13
Note: ”-” means the current function is not set or opened,” √”means the current function is in
default state, ”open” means the current function is turned on by default, “close” means the
current function is turned off by default.
4 TT-1007D-MARINE operation instruction
4.1 Turn on TT-1007D-MARINE
Connect the power and video cables correctly, Turn on power,
TT-1007D-MARINE automatically
start up, power indicator light.
CCD video output interface display system initialization, then camera pull the lens recently first
and pushed to the farthest stop; PTZ automatically rotate at horizontal and vertical direction.
If system self-test succeed, CCD video display PTZ address, baud rate and protocol.
If system self-test fails, CCD video interface will display self-test failure message in the lower left
corner. A feature hint system self test failed
Pic.10
Self-test fails with the message as below:
PAN FAIL—horizontal self-test failure
TITL FAIL-vertical self-test failure
CAM FAIL—module initialization failure
P/T FAIL—horizontal / vertical self-test failure
T/Z FAIL—vertical / module self-test failure;
P/T/Z FAIL—horizontal / module self-test failure
When the horizontal and vertical test fails, if the climate temperature is less than 5°C,
TT-1007D-MARINE will automatically turn on heating function and self-check again after 20