68
Intel
®
Server System SR1690WB Service Guide
System Environmental Specifications
*The system requires the use of a shielded LAN cable to comply with Immunity
regulatory requirements. Use of non-shield cables may result in the product having
insufficient protection against electromagnetic effects, which may cause improper
operation of the product.
Table 8. System Environmental Specifications
Temperature
Non-operating
Operating
-40 ° to +70 °C.
10° C to 35° C (50° F to 90° F) with the maximum rate of change not to
exceed 10° C per hour
Humidity
Non-operating
90% relative humidity (non-condensing) at 35°C.
Shock
Operating
Unpackaged
Packaged
2.0 g, 11 msec, 1/2 sine
Trapezoidal, 25 g, velocity change 136 inches/sec
Non-palletized free fall at a height of 30 inches
Acoustic noise
Sound Pressure: 55 dBA (rack mount) in an idle state at typical office
ambient temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle
state at typical office ambient temperature. (23 +/- 2 degrees C).
Electrostatic
discharge (ESD)*
+/-12 kV except I/O port +/-8 KV, per Intel Environmental Test Specification.
Summary of Contents for SR1690WB - Server System - 0 MB RAM
Page 6: ...vi Intel Server System SR1690WB Service Guide...
Page 14: ...xiv Intel Server System SR1690WB Service Guide...
Page 18: ...xviii Intel Server System SR1690WB Service Guide...
Page 102: ...84 Intel Server System SR1690WB Service Guide...
Page 122: ...104 Intel Server System SR1690WB Service Guide...
Page 128: ...110 Intel Server System SR1690WB Service Guide...
Page 149: ...Intel Server System SR1690WB Service Guide 131 Intel Intel Intel Web UL...
Page 150: ...132 Intel Server System SR1690WB Service Guide ITE ITE 5V...
Page 151: ...Intel Server System SR1690WB Service Guide 133...
Page 152: ...134 Intel Server System SR1690WB Service Guide ESD ESD ESD ESD ESD...
Page 153: ...Intel Server System SR1690WB Service Guide 135...
Page 154: ...136 Intel Server System SR1690WB Service Guide...