LED Information
The Intel
®
Server Board SE7320SP2 / SE7525GP2 includes LEDs that can aid in troubleshooting
your system. A table of these LEDs with a description of their use is listed below.
LED Name
Function
Location
Color
Correction
ID
Aid in server
identification from the
back panel
Control panel and
board rear left
corner
Blue
Press ID LED button or user
Server Management
software to turn off the LED.
System fault
Visible fault warning
Control panel and
board rear left
corner
Green or Amber
On = No Fault
Green Blink = degraded
Amber = critical error or
non-recoverable
Amber blink = non-critical
ATA activity
Control panel
Control panel and
board left side
Green
Blinking = Activity. No action
required.
Memory fault
1–6
Identify failing memory
module
DIMM end front of
board
Amber
On = Fault
POST code 1–4
(LSB, bit1, bit2,
MSB)
Display boot 80 POST
code
Left rear of board
Each LED can be
Off, Green,
Amber, Red
See the POST code table
Fan Pack Fault
Warn on fan failure
Front center board
Amber
On = Fault
CPU 1 & 2 Fan
Fault
Identify fan failure
Front center board
Amber
On = Fault
CPU 1 & 2
Fault
Identify processor failure
1” behind processor
socket
Amber
On = Fault
5v Standby
Identify 5v standby
power on state
Front left board
Amber
On = 5v standby power on
Power LED
Identify the power state
of the system
Control panel
Green
Off = Power is off (off or
S5)
On = Power on or S0)
Slow Blink = Low power
state (S1 – S3)
Intel Server Board SE7320SP2 / SE7525GP2 User Guide
46