Intel®
Server Board S1200V3RP TPS
Intel®
Technology Support
Revision 1.2
41
Value Vector
Capabilities and Features
2.0
Power and Thermal
Policies
Concurrent policies
16
Power limiting
– OS operational
Power limiting
– during OS failure
Power reduction upon temperature excursion
Response SLA
1s(adj)
Avoid Triggering HW
Protection
Reduce power consumption to prevent tripping DC
circuit breaker
Reduce power consumption during SMART ride-
through or overcurrent
Interfaces
IPMI-based commands over SMBus* (monitoring,
control, and alert)
5.3.1
Hardware Requirements
NM is supported only on platforms that have the NM FW functionality loaded and enabled on
the Management Engine (ME) in the SSB and that have a BMC present to support the external
LAN interface to the ME. NM power limiting feature requires a means for the ME to monitor
input power consumption for the platform. This capability is generally provided by means of
PMBus*-compliant power supplies although an alternative model using a simpler SMBus* power
monitoring device is possible (there is potential loss in accuracy and responsiveness using non-
PMBus* devices). The NM SmaRT/CLST feature requires specific PMBus*-compliant power
supplies as well as additional hardware on the baseboard.