Intel®
Server Board S1200V3RP TPS
Appendix B: Integrated BMC Sensor Tables
Revision 1.2
221
-
A: Auto-rearm
-
M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which is 1 or 2 (positive or negative hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED.
Standby
Some sensors operate on standby power. You can access these sensors and/or
generate events when the main (system) power is off but AC power is present.
Table 71. Integrated BMC Core Sensors
Full Sensor
Name
(Sensor name
in SDR)
Se
ns
or
#
Platform
Applicabilit
y
Sensor
Type
Event/R
eading
Type
Event Offset Triggers
Contrib.
To
System
Status
Assert
/De-
assert
Reada
ble
Value/
Offset
s
Event
Data
Rearm St
an
db
y
Power Unit
Status
(Pwr Unit
Status)
01
h
All
Power
Unit
09h
Sensor
Specifi
c
6Fh
00 - Power down
OK
As
and
De
–
Trig
Offset
A
X
02 - 240 VA power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control failure
Fatal
06 - Power unit failure
Power Unit
Redundancy
1 (Pwr Unit
Redund)
02
h
Chassis-
specific
Power
Unit
09h
Generi
c
0Bh
00 - Fully Redundant
OK
As
and
De
–
Trig
Offset
M
X
01 - Redundancy lost
Degrad
ed
02 - Redundancy
degraded
Degrad
ed
03 - Non-redundant:
sufficient resources.
Transition from full
redundant state.
Degrad
ed
04
– Non-redundant:
sufficient resources.
Transition from
insufficient state.
Degrad
ed
05 - Non-redundant:
insufficient resources
Fatal
06
– Redundant:
degraded from fully
redundant state.
Degrad
ed
07
– Redundant:
Transition from non-
redundant state.
Degrad
ed
IPMI
Watchdog
03
h
All
Watchd
og 2
Sensor
Specifi
00 - Timer expired,
status only
OK
As
–
Trig
Offset
A
X
Summary of Contents for S1200V3RP
Page 14: ......