Hardware Installations and Upgrades
80
Intel
®
Server Chassis P4000M Service Guide
screws firmly, starting with the screws at the center of the server/workstation board. Make cable
connections per instructions in the Intel
®
server/workstation board
Service Guide
and/or
Quick Start
User’s Guide
.
7. If removing a server board, disconnect all cables connected to the server board.
8. Remove the mounting screws, starting with the screws at the center of the server/workstation board.
Remove the server board.
9. If desired, install any PCI Add-in boards. For instructions, see “Installing PCI Add-in Board(s)”
10. Re-install the front bezel assembly. For instructions, see “Installing the Front Bezel (Pedestal Only)”.
11. Re-install the chassis cover. For instructions, see “Installing the Chassis Cover”.
12. Plug all peripheral devices and the AC power cable into the server.
13. Power up the server.
Connecting and Disconnecting Cables to or from
Server Workstation Board
CAUTION
Use caution when routing cables to ensure that cables do not obstruct fan airflow.
1. See your
Intel
®
Server/Workstation Board Service Guide
or
Quick Start User’s Guide
for cable
connection locations.
2. If your server has a hot swap power supply, secure the cables (that route toward the
server/workstation board) to the chassis.
Connecting Cables to Server/Workstation Board
1. If your server has a hot swap power supply, connect the cables (that route toward the
server/workstation board) to the chassis.
2. See your
Intel
®
Server/Workstation Board Service Guide
or
Quick Start User’s Guide
for cable
connection locations.
Removing Cables from Server/Workstation Board
1. If your server has a hot swap power supply, remove the cables (that route toward the
server/workstation board) to the chassis.
2. See your
Intel
®
Server/Workstation Board Service Guide
or
Quick Start User’s Guide
for cable
connection locations.
Rack-mounted Systems
Your Intel
®
Server Chassis P4000M family can be mounted into a rack. Intel
®
provides a tool-less
rail kit and a cable management arm to mount this server chassis into a rack. When installing the
chassis into a rack, Intel
®
recommends you install systems from the bottom of the rack to the top.
In other words, install the first system in the rack into the bottom position of the rack, the second
system in the second position from the bottom, and so on.