6. Remove system fan by pushing the tabs outward and disengaging from its snap-in bracket (see letter
B
).
Figure 33. Removing fixed system fan from chassis
Installing the Fixed Fan
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the air duct if the air duct is installed. For instructions, see “Removing the Airduct”.
5. Insert the fan cable in the fan bracket as shown below (see letter
A
). Pay attention to the fan cable
connector color. The fan with blue fan cable connector should be installed in fan2 bracket; the fan
with white fan connector should be installed in fan 1 bracket.
Figure 34. Inserting the fan cable in the corresponding fan bracket