Page 28
P175E
Keypad & Radio Panic Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = All keypads 1-8)
KEYPADS WITH BUTTONS 4&6 FIRE ENABLED
By pressing the buttons 4&6 simultaneously it is possible to create a Fire alarm report to the dialer. If
you want this Fire function enabled at any of the keypads you must enable the operation at this address.
P176E
Keypads with the Panic Buttons 4&6 Enabled -
Option keypad 1-8
(Default = None)
FIRE ALARM TO KEYPAD BUZZER
The two button fire function at the keypads (P176E) can be audible or silent at the keypads. If a silent
fire alarm is required the option must be turned off at this address. For an audible Panic Beep at the
keypad/s turn this option on.
P177E
Fire Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = None)
KEYPADS WITH BUTTONS 7&9 MEDICAL ENABLED
By pressing the buttons 7&9 simultaneously it is possible to create a Medical alarm report to the dialer. If
you want this Medical function enabled at any of the keypads you must enable the operation at this
address.
P178E
Keypads with the Medical Buttons 7&9 Enabled -
Option keypad 1-8
(Default = None)
MEDICAL ALARM TO KEYPAD BUZZER
The two button medical function at the keypads (P178E) can be audible or silent at the keypads. If a
silent medical alarm is required the option must be turned off at this address. For an audible Medical
Beep at the keypad/s turn this option on.
P179E
Medical Alarm to Keypad Buzzer -
Option keypad 1-8
(Default = None)
MONITOR BUTTON CAN DISARM MONITOR MODE
The Alarm panel can be set up so that the
“
Monitor
”
button at the keypad can be a single press to arm
Monitor Mode. During the Monitor Armed state the
“
Monitor
”
button can also be used to Disarm Monitor
Mode with a single press provided the keypad concerned has this option turned on. If you do not want
single button disarming of monitor mode at any keypads then ensure this option is off for the keypad/s
concerned.
Also, after Monitor Mode has been armed, if the
“
Enter
”
button is pressed, all exit & entry
delays will be removed making the whole alarm instant. If the
“
Enter
”
button is not pressed then all exit
and entry delays will apply.
P180E
Monitor Button can Disarm Monitor Mode -
Option keypad 1-8
(Default = 1 & 4)
MISCELLANEOUS PANEL OPTIONS # 1
This address (P169E) is used to select the first set of optional panel functions.
P169E 1E
Turn Off keypad LEDS at the end of exit time - Default off
2E
Keypad Panic Button delayed or instant - Default off
3E
Installer Code has direct access to Program Mode - Default on
Option 1
Turn off keypad LEDS at end of exit time
- If this option is off (LED 1 Off) then the keypad LEDS
remain working at all times. If it is on (LED 1 On), the keypad LEDS will automatically turn off at the end
of the exit delay time (NOTE: the backlight LED
’
s on an LED keypad will remain on). The LEDS will turn
on again if the alarm is unset, an alarm occurs or any button on the keypad is pressed.
Option 2
Keypad Panic Button delayed or instant
- If this option is off (LED 2 Off) any press of the
“
Panic
”
button on the LED keypads will result in an immediate panic alarm. If it is turned on (LED 2 On) there will
now be a 2 second delay on the panic button. The button must be held down continuously for 2 seconds
to create a panic alarm.
Option 3
Installer Code has direct access to Program Mode -
If this option is off (LED 3 Off) the installer code
Summary of Contents for Elite Version 8D
Page 56: ...Page 56 ...