Option 2 Report Keypad Fire Alarm - If the 2 button
“
4&6
”
Fire alarm feature is enabled then turning this option
on allows the Fire Alarm to be sent via the dialer to a monitoring station.
Option 3 Report Keypad Fire Alarm - If the 2 button
“
4&6
”
Fire alarm feature is enabled then turning this option
on allows the Fire Alarm to be sent via the dialer to a monitoring station.
DIALER REPORTING OPTIONS
“
C
”
This address (P188E) is used to enable or disable various alarm reports to the Dialer.
P188E 1E
Report Arm/Disarm - Default on
2E
Report Monitor Mode Arm/Disarm - Default on
3E
Report Disarm only after an Activation - Default off
4E
Report Monitor Mode Disarm only after an Activation - Default off
5E
Report
24 Hour Alarms when set to Domestic/Voice mode - Default off
6E
Send Arm immediately - Default off
7E
Send Zone alarms in Monitor Mode - Default off
8E
Spare - Default off
Option 1
Report Arm/Disarm -
If this option is on then all Arm/Disarm signals will be reported to a central
Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
Option 2
Report Monitor Mode Arm/Disarm -
If this option is on then all Monitor Mode Arm/Disarm signals will
be reported to a central Monitoring Station if Contact ID or 4 + 2 is set as the reporting format.
Option 3
Send unset after activation
- If this option is on, the panel will not normally send an Arm/Disarm signal
to the monitoring company, however, if a zone alarm occurs then the panel will send a Disarm following
the disarming of the panel to show it has been turned off by a valid user.
Option 4
Send Monitor Mode unset after activation -
If this option is on, the panel will not normally send a
Monitor Mode Arm/Disarm signal to the monitoring company, however, if a zone alarm occurs then the
panel will send a Disarm and group bypass restore following the disarming of the panel to show it has
been turned off by a valid user.
Option 5
Report
24 Hour Alarms when set to Domestic/Voice mode -
When the panel is set to send alarms via
domestic or voice mode, NO alarms will normally be sent for 24 hour zones. If 24 hour alarms are
required to be reported in Domestic/Voice mode then this option must be turned on.
Option 6
Send Arm immediately
- If this option is on, the arm report is sent immediately the panel is armed. If
the option is turned off, the arm signal will be sent at the expiry of the exit delay timer.
Option 7
Send Zone alarms in Monitor Mode
- If this option is on, any Monitor Mode zone alarms will be
reported via the dialer. If it is off, no Monitor Mode zone alarms will be transmitted via the dialer.
KEYPAD LISTEN-IN OPTIONS
The panel provides the facilities to use the buzzer in the keypad as a speaker to listen to the call being made by the
dialer. To use this feature a 5th wire must be connected between the panel and a keypad using the listen-in
terminals.
P189E 1E
Listen-in Enabled when dialing only and in Disarmed State - Default on
2E
Listen-in Enabled when dialing only and in Armed State - Default on
3E
Listen-in Enabled when dialing only and in Monitor Mode - Default on
4E
Listen-in Enabled through the entire call only in Disarmed state - Default on
5E
Listen-in Enabled through the entire call only in Armed State - Default on
6E
Listen-in Enabled through the entire call only in Monitor Mode - Default on
7E
Listen-in Enabled when the panel answers a call - Default on
8E
Listen-in on at All Times - Default off
OUTPUT # 1 LISTEN-IN OPTIONS
The panel provides the facilities to use a horn speaker connected to Output 1 to listen to the call being made by the
dialer. To use this feature a horn speaker MUST be connected to Output 1 and the output set for siren Mode (P31E
Option 5).