Page 45
P141E Non-Latching 24 Hour Zone Zones 1-8 ( Default = No zones)
Page 22
P142E Lockout Zone Zones 1-8 ( Default = No zones)
Page 22
P143E Day Zone Zones 1-8 ( Default = No zones)
Page 22
P144E Permanent Day Zone Zones 1-8 ( Default = No zones)
Page 22
P145E Can Arm if not Sealed Zones 1-8 ( Default = No zones)
Page 22
P146E Report excludes to Dialer Zones 1-8 ( Default = All zones)
Page 22
P147E Multiple Alarms to Dialer Zones 1-8 ( Default = All zones)
Page 22
P148E Report Zone Tampers to Dialer Zones 1-8 ( Default = All zones)
Page 22
P149E Zones Report to Area B Account Zones 1-8 ( Default = No zones)
Page 22
P150E Zones with Inactivity Timer Zones 1-8 ( Default = No zones)
Page 22
Radio Pendant Options
“
A
”
P151E Radio Key # 1 Opt (Default= 1,3,4) P151E-P158E Options
Page 26
P152E Radio Key # 2 Opt (Default= 1,3,4)
1 = Assigned to Area
“
A
”
Page 26
P153E Radio Key # 3 Opt (Default= 1,3,4)
2 = Assigned to Area
“
B
”
Page 26
P154E Radio Key # 4 Opt (Default= 1,3,4)
3 = Can Arm Area
Page 26
P155E Radio Key # 5 Opt (Default= 1,3,4)
4 = Can Disarm Area
Page 26
P156E Radio Key # 6 Opt (Default= 1,3,4)
5 = Can arm Monitor Mode
Page 26
P157E Radio Key # 7 Opt (Default= 1,3,4)
6 = Can disarm Monitor Mode
Page 26
P158E Radio Key # 8 Opt (Default= 1,3,4)
7 = Spare Page 26
8 = Disabled if Panel is in Alarm
**Radio Pendant Options
“
B
”
**
P161E Radio Key # 1 Options (Default= None) P161E-P168E Options
Page 26
P162E Radio Key # 2 Options (Default= None)
1 = Pendant Can Turn Output On
Page 26
P163E Radio Key # 3 Options (Default= None)
2 = Pendant Can Turn Output Off
Page 26
P164E Radio Key # 4 Options (Default= None)
3 = Visonic Powercode Battery Low
Page 26
P165E Radio Key # 5 Options (Default= None)
4 = Spare
Page 26
P166E Radio Key # 6 Options (Default= None)
5 = Send Panic Alarm Through Dialer
Page 26
P167E Radio Key # 7 Options (Default= None)
6 = Causes Immediate Panic
Page 26
P168E Radio Key # 8 Options (Default= None)
7 = Causes Delayed Panic ( 1.5 Sec) Page 26
8 = Ness Battery Low
Miscellaneous Panel Options # 1
P169E Misc. Panel Options # 1 P169E Options
Page 28
(Default= 3)
1 = Turn KP LED
’
s off when Armed
2 = Keypad
“
Panic
”
Button instant or delayed
3 = Direct access to program mode for the installer code.
Miscellaneous Panel Options # 2
P170E Misc. Panel Options P170E Options
Page 29
(Default= None)
1 = Panel Tamper NC or EOL
2 = Installer Lockout
3 = Disable Mains Fail Test
4 = Arm only if sealed
5 = No audible keypad beep on supervised radio fault
6 = No audible keypad beep on Zone Inactivity Timeout
7 =
“
Control
”
Button Disables Day Zones
8 = Silent 24 Hour Zone (No Keypad Beep)
Keypad Partition Assignment
P171E Keypads Assigned To Partition
“
A
”
-
Value Keypad 1-8
(Default= All Keypads)
Page 27
P172E Keypads Assigned To Partition
“
B
”
-
Value Keypad 1-8
(Default= No Keypads)
Page 27
Keypads with Panic Button Enabled
P173E Keypads with Panic Button Enabled -
Value Keypad 1-8
(Default= All Keypads)
Page 27
Keypads with 1&3 Panic Enabled
P174E Keypads with 1 & 3 Panic Function Enabled -
Value Keypad 1-8
(Default= No Keypads)
Page 27
Keypad and Radio Panic Beeps to Keypad Enabled
P175E Keypad & Radio Panic Beeps to Keypad Enabled -
Value Keypad 1-8
(Default= All Keypads)
Page 27
Summary of Contents for Elite Version 8D
Page 56: ...Page 56 ...