Page 44
Partition
“
A
”
Options
P110E Partition
“
A
”
Options P110E Options
Page 17
(Default= 4 & 5)
1 = Arm Button Required Before Code to Set
2 = Monitor Button Required Before Code to Set Monitor Mode
3 = Code required to Set
4 = Arm Button can disarm during Exit Delay
5 = Monitor Button can disarm Monitor Mode at any time
6 = No Exit beeps to Keypads in Monitor Mode
7 = Enable Key-switch
8 = Key-switch Mode
Partition
“
A
”
Output Options
P111E Area
“
A
”
Opt. O/P # 1 (Default= None) P111E-P118E Options
Page 18
P112E Area
“
A
”
Opt. O/P # 2 (Default= None)
1 = Arm Status to Output
P113E Area
“
A
”
Opt. O/P # 3 (Default= None)
2 = Monitor Arm Status to Output
P114E Area
“
A
”
Opt. O/P # 4 (Default= None)
3 = Disarm Status to Output
P115E Area
“
A
”
Opt. O/P # 5 (Default= None)
4 = Pendant Chirps on Arm
P116E Area
“
A
”
Opt. O/P # 6 (Default= None)
5 = Pendant Chirps on Monitor Mode Arm
P117E Area
“
A
”
Opt. O/P # 7 (Default= None)
6 = Pendant Chirps on Disarming
P118E Area
“
A
”
Opt. O/P # 8 (Default= None)
7 = Pulse on Arming to Output
8 = Pulse on Disarming to Output
Partition
“
B
”
Options
P120E Partition
“
B
”
Options P120E Options
Page 19
(Default= 4 & 5)
1 = Arm Button Required Before Code to Set
2 = Monitor Button Required Before Code to Set Monitor Mode
3 = Code required to Set
4 = Arm Button can disarm during Exit Delay
5 = Monitor Button can disarm Monitor Mode at any time
6 = No Exit beeps to Keypads in Monitor Mode
7 = Enable Key-switch
8 = Key-switch Mode
Partition
“
B
”
Output Options
P121E Area
“
B
”
Opt. O/P # 1 (Default= None) P111E-P114E Options
Page 20
P122E Area
“
B
”
Opt. O/P # 2 (Default= None)
1 = Arm Status to Output
P123E Area
“
B
”
Opt. O/P # 3 (Default= None)
2 = Monitor Arm Status to Output
P124E Area
“
B
”
Opt. O/P # 4 (Default= None)
3 = Disarm Status to Output
P125E Area
“
B
”
Opt. O/P # 5 (Default= None)
4 = Pendant Chirps on Arm
P126E Area
“
B
”
Opt. O/P # 6 (Default= None)
5 = Pendant Chirps on Monitor Mode Arm
P127E Area
“
B
”
Opt. O/P # 7 (Default= None)
6 = Pendant Chirps on Disarming
P128E Area
“
B
”
Opt. O/P # 8 (Default= None)
7 = Pulse on Arming to Output
8 = Pulse on Disarming to Output
Programming Zone Doubling & EOL Options
P130E Zone Doubling & EOL Options - Value 1-8 (Default = 1-4 On, 4 zone panel with 2k2 EOL)
Page 20
**Programming Zone Options**
P129E 24 Hour Fire Zone Zones 1-8 ( Default = No zones)
Page 21
P131E Partition
“
A
”
Zones Zones 1-8 ( Default = All zones)
Page 21
P132E Partition
“
B
”
Zones Zones 1-8 ( Default = No zones)
Page 21
P133E Zone is NC or NO Zones 1-8 ( Default = All zones are NC)
Page 21
P134E Radio Zone Input Zones 1-8 ( Default = No zones)
Page 21
P135E Manually excludable Zone Zones 1-8 ( Default = All zones)
Page 21
P136E Auto-excludable Zone Zones 1-8 ( Default = All zones)
Page 21
P137E Handover Zone Zones 1-8 ( Default = No zones)
Page 21
P138E Two Trigger Zone Zones 1-8 ( Default = No zones)
Page 21
P139E Monitor Mode Zone Zones 1-8 ( Default = Zone 1)
Page 21
P140E 24 Hour Zone Zones 1-8 ( Default = No zones)
Page 22
Summary of Contents for Elite Version 8D