100 |
P a g e
Note:
Measure the fluid level with the dipstick placed in the
bore, but do not thread the dipstick into the bore.
6.
In the Totals screen of the display screen unit, note the Job Total
volume (gallons or liters).
7.
Calculate the Small Pump Calibration Factor.
(Start Volume – End Volume)(Old Calibration Factor)
Job Total
8.
On the Password screen of the display screen unit, enter the
password. The Service screen will appear.
9.
On the Service screen, use up and down arrows [1R] and [3R] to
select the Small Pump Calibration Factor.
10.
Use the keys corresponding to the up and down arrows [1R] and
[3R] to enter the new calibration factor. Press the Enter button
[2R].
Tip:
For greatest accuracy use all three decimal places.
Example:
Starting tank volume = 425 gallons
Ending tank volume = 50 gallons
Measured volume = 375 gallons
Job total = 378 gallons
Old calibration factor = 1000
(425 – 50)(1000)
378
= Calibration Factor
= 992