TwinLock B600 CashProtect
Trouble Shooting
Manual V.1.04A
75
Close&Code
!
User has not been authorized to close locks by entering his code.
✓
Consult your system manager. See above.
Code card
!
User has not been authorized to use a code card.
✓
Consult your system manager. See above.
Disarm BAS
!
User has not been authorized to disarm a burglar alarm system.
✓
Consult your system manager. See above.
No release!
!
User has not been authorized to enter code of any kind.
✓
Consult your system manager. See above.
Open
!
User has not been authorized to open locks.
✓
Consult your system manager. See above.
PIN code
!
User has not been authorized to enter PIN code.
✓
Consult your system manager. See above.
Service
!
User has not been authorized to export protocols.
✓
Consult your system manager. See above.
Block period
!
When trying to open the lock
- a user has entered wrong code three times
- a block period of 90 minutes has been activated because at least one
lock was closed during a terminal change
- a time program, which blocks the lock, has been active.
✓
Wait until the block period ends and open then.
✓
Check the protocol / Have the staff responsible for security check whether
someone has tried to manipulate the system.
Bus A/B Receive
Bus A/B Transmit
!
A lock cannot be addressed via bus A / bus B. A bus cable connection might
be plugged in incorrectly or the cable might be out of order.
✓
If you cannot solve the problem, contact technical support.
Codes identical!
!
PIN code, which should have been changed, has been repeated instead.
✓
Change the PIN code.
Disarm code?
!
TwinAlarm signals an error during disarming the burglar alarm system (BAS):
TwinAlarm cannot disarm BAS because no code authorised to disarm the BAS
has been registered.
✓
Activate alarm device TwinAlarm and register code at the lock while TwinAlarm
is activated.