TwinLock B600 CashProtect
Operation
Manual V.1.04A
30
4.7.1
Fields and Boxes of the User Matrix
The user matrix can be displayed and edited, as the case may be, via PC software.
Caution
Users cannot open locks in case they have not been
authorised sufficiently.
Unmark the boxes / squares for authorisation only after reading
this manual and, if required, after having consulted an expert on
system.
Mark further boxes, if required, like “Card”, for example.
.
In order to be able to open locks, for example, a user has to be authorised to do so.
Users and lock masters (= user 00) can be authorised to open locks by the system
manager, who cannot open locks himself.
Note
In addition to authorizing users individually, the system manager
can define two groups of users (‘CIT’ on page ‘Settings
/Code
’ of
the PC software) and set conditions for opening for the groups.
See section ‘Operation with “User groups” Selected’ further on in
this chapter.
See below a list of all boxes and fields for users.
Boxes can be marked / unmarked individually for users.
Fields and Boxes / Squares for Users
User
Consecutive user number, not to be edited.
Ex works, the user is identified with this number.
Also see
‘Personnel no.’
below.
Name
Field for user name;
Name entered here will be used in the protocol.
PIN code
Enable entering PIN code
Card
Enable inserting a code card
1 of x
Enable selecting one way of code input, PIN code or card
2 of x
Enable selecting two ways out of three possible ways of code
input (with TwinLock BioPIN only)
Quick open code
Enable opening locks even when they are blocked (override
active time programs)
Release
General authorisation to enter code
Open locks
Enable opening locks
Close & code
Enable closing locks with code input
Service
Enable importing the configuration / assigning week programs
Dual code
Enable opening / closing triggered by this user autonomously,
override
even with two men rule activated.
Caution
With systems with a burglar alarm system (BAS), users can
open locks only in case the box ‘Disarm’
is marked for them.
Do not unmark box
Disarm
for users supposed to open locks.
This also applies to the lock master.
Disarm
Enable disarming an optional burglar alarm system (not available
with TwinLock B600 CashProtect).