Functions
INSYS GSM 4.3 I4
44
logout/login will only be performed, if the SMS has been sent or an existing data or audio
connection has been terminated.
Configuration with HSComm
In order to
enable the scheduled logout/login
, activate on the “Basic Settings”
tab on the “System Monitoring” panel the check box “logout”. Enter the time
into the entry field “time” at which the INSYS GSM 4.3 I4 logs out from the
GSM network daily. Enter a time in minutes (minimum one minute, maximum
98 minutes), for which the device waits in logged out state before it logs in
into the GSM network again, into the entry field “duration”. If the value 0 is
entered as time here, the scheduled logout/login will be disabled.
In order to
enable the scheduled logout/login with reset of the INSYS GSM 4.3
I4
, activate on the “Basic Settings” tab on the “System Monitoring” panel the
check box “logout with reset”. Enter the time into the entry field “time” at
which the INSYS GSM 4.3 I4 logs out from the GSM network daily and per-
forms a subsequent restart.
Configuration with AT commands
In order to
enable the scheduled logout/login
,
use the command
Replace
<hh:mm>
with the desired time and
enter a value for the logout duration between
one and 98 minutes instead of
<t>
.
AT**LOGOUT=<hh:mm>,<t>
In order to
enable the scheduled logout/login
with subsequent reset of the INSYS GSM 4.3
I4
, use the command
AT**LOGOUT=<hh:mm>,99
In order to
disable the scheduled logout/login
completely
, use the command
AT**LOGOUT=
In order to
query the scheduled logout/login
,
use the command
AT**LOGOUT?
11.10
Establishing or Accepting a Data Connection
The INSYS GSM 4.3 I4 can call another modem via the GSM network and establish a data
connection. After dialling a phone number, the INSYS GSM 4.3 I4 synchronises with the
called modem and opens a data connection with the transmission speed allowed by the
GSM network. This is usually 9600 bit/s.
The speed, which is set at the serial interface of the INSYS GSM 4.3 I4 at the time of con-
nection establishment, will not be changed.
All incoming characters are transmitted to the other (called) modem during the active
data connection. Therefore, AT commands are not processed during a connection. The
INSYS GSM 4.3 I4 must be changed to command mode again using an "Escape sequence"
that it processes AT commands again during an active connection. Then, the local INSYS
GSM 4.3 I4 processes the entered characters as AT commands and does not transmit