X10 PROGRAMMING OPTIONS 

LampLinc Dimmer is backward-compatible with X10, meaning that it can respond to X10 commands from 
an X10 Controller.  However, 

to operate LampLinc Dimmer in X10 mode

you must first set up an 

X10 Primary Address

.  As It ships from the factory, or after a factory reset procedure, LampLinc Dimmer 

will have no X10 Primary Address set up.

 

Setting the X10 Primary Address 

You must do this before LampLinc Dimmer will respond to X10 commands.

  You can use any of the 

256 possible X10 addresses for the X10 Primary Address.  

1.  Press and hold the black 

SET Button

 on LampLinc Dimmer for 3 seconds.  The white Status LED will 

begin flashing and the lamp you are controlling will blink to confirm that you are setting up an X10 
Primary Address. 

2.  Use an X10 Controller to send an 

X10 ON

 command 

THREE TIMES

 (e.g. A1 ON A1 ON A1 ON).  

You have about 30 seconds to perform this step before setup mode expires.  (NOTE:  If you send an 

X10 OFF

 command during this step, Local Control will be disabled.  See the next section for an 

explanation.) 

3.  Once LampLinc Dimmer has received the X10 Address and X10 ON or X10 OFF 

THREE TIMES

, the 

Status LED on LampLinc Dimmer will stop flashing and the X10 Primary Address will be set. 

Removing the X10 Primary Address 

1.  Press and hold the black 

SET Button

 on LampLinc Dimmer for 3 seconds.  The white Status LED will 

begin flashing and the lamp you are controlling will blink to confirm that you are setting up an X10 
Primary Address. 

2.  Press and hold the black 

SET Button

 on LampLinc Dimmer for 3 seconds 

again

 and send any X10 

address 

THREE TIMES

 (e.g. A1 ON A1 ON A1 ON).  The white Status LED will stop flashing and the 

lamp you are controlling will blink again to confirm that you have removed the X10 Primary Address. 

Enabling or Disabling Local Control 

Local Control allows you to manually turn on the lamp you plugged into LampLinc Dimmer by using the 
switch on the lamp itself, without sending a command from an X10 or INSTEON Controller.  By default, 
Local Control is enabled.  You can disable Local Control by setting the X10 Primary Address using an 
X10 OFF command in Step 2 above.  Remember that if the switch on the lamp itself is turned off, 
LampLinc Dimmer will not be able to control the lamp. 

Setting the X10 On-Level for the X10 Primary Address 

The X10 On-Level is the brightness that the lamp you are controlling will go to when you turn it on using 
an X10 Controller.  The X10 On-Level can be adjusted from OFF to 100% brightness.  The default is 
100% 

1.  Using the BRIGHT, DIM, ON, or OFF Buttons on any Controller, 

adjust the brightness

 of the lamp 

you are controlling to the desired On-Level. 

2. Tap 

the 

SET Button

 on LampLinc Dimmer 

ONCE

.  The lamp you are controlling will blink to confirm 

the X10 On-Level setting. 

Summary of Contents for LampLinc 2456D2

Page 1: ...INSTEON LampLinc INSTEON Lamp Dimmer For models 2456D2 LampLinc Dimmer two prong 2456D3 LampLinc Dimmer with ground pin...

Page 2: ...the X10 Primary Address 11 Removing the X10 Primary Address 11 Enabling or Disabling Local Control 11 Setting the X10 On Level for the X10 Primary Address 11 Enabling X10 Resume Dim 12 Setting the X1...

Page 3: ...evice is a two way repeater And affordable not just because of low cost but because INSTEON also works with legacy X10 devices An INSTEON home grows in value with every INSTEON device you add making l...

Page 4: ...les together by plugging them into each other Stacked modules may overheat and stop functioning Caution Read and understand these instructions before installing and retain them for future reference La...

Page 5: ...hed wall receptacle The white Status LED on the side will illuminate steadily 3 Plug the lamp you want to control into the controlled outlet on the bottom of LampLinc Dimmer 4 The lamp you plugged in...

Page 6: ...nc Dimmer Press and hold the ON Button of the pair for 10 seconds To confirm that it is in Linking Mode ControLinc s Status LED will begin blinking C KeypadLinc Choose the ON Button you want to use fo...

Page 7: ...top LED in its LED Bar B ControLinc Tabletop Controller Press and hold the OFF Button of the ON OFF Button Pair you used for controlling LampLinc Dimmer for 10 seconds To confirm that it is in Unlinki...

Page 8: ...he default is 0 5 second 1 Using the ON OFF Button Pair that you already linked LampLinc Dimmer to set the INSTEON Controller to Linking Mode by pressing and holding the ON Button of the pair for 10 s...

Page 9: ...setup step by placing the Controller in Scene Setup Mode also called Multilink Mode Refer to your INSTEON Controller s User s Guide for detailed instructions on how to set it to Scene Setup Mode The f...

Page 10: ...nd restore its factory default settings This procedure will clear the unit of all INSTEON Links and any programmed On Levels Ramp Rates X10 Primary Address or X10 Scene Addresses 1 Before resetting a...

Page 11: ...1 Press and hold the black SET Button on LampLinc Dimmer for 3 seconds The white Status LED will begin flashing and the lamp you are controlling will blink to confirm that you are setting up an X10 Pr...

Page 12: ...Rate of the lamp you are controlling Adjust the X10 Ramp Rate to be faster by pressing the BRIGHT Button or adjust it to be slower by pressing the DIM Button The table below gives the approximate rela...

Page 13: ...nit code 3 Set the On Level for the X10 Primary Address by adjusting LampLinc Dimmer s brightness using any Controller If you skip this step the current On Level will be used 4 Send the following X10...

Page 14: ...Scene Address and On Level 1 Using an X10 Controller send the CLEAR Sequence 2 Set the On Level for the X10 Scene Address by adjusting LampLinc Dimmer s brightness using any controller If you skip th...

Page 15: ...Dimmer s X10 Primary Address house code and unit code 3 Use any controller to adjust LampLinc Dimmer s brightness so it corresponds to the Ramp Rate you want in the table below Brighter is faster 4 Se...

Page 16: ...to overcome signals getting weaker is to increase the coverage of the mesh network by introducing more INSTEON devices It is possible that some audio video products computers power strips or other el...

Page 17: ...turn on or turn off when you set the X10 Address for the product If turned on the BoosterLinc technology may interfere with INSTEON KeypadLinc 6 with Integrated Dimmer 12073W 12073WB and 12073WW Swit...

Page 18: ...r INSTEON Controller with both of them plugged into the same outlet Once linked move them to the desired locations The lamp does not appear to turn on or off when a signal is sent The Ramp Rate may be...

Page 19: ...e lamp flashes to acknowledge the X10 On Level setting If you are not using LampLinc Dimmer in X10 mode this setting will be ignored My LampLinc Dimmer doesn t respond to X10 address A1 when I first s...

Page 20: ...Yes X10 Features X10 Primary Address 1 optional comes unassigned X10 Scene Addresses 255 possible X10 Status Response Supported X10 Resume Dim Supported by setting X10 Primary Address On Level to zer...

Page 21: ...ackage the product with the RA clearly printed on the outside of the package and send the product along with all other required materials to Smarthome Inc ATTN Receiving Dept 16542 Millikan Ave Irvine...

Reviews: