background image

Icon Appliance Adapter User’s Guide 

 

Page 7 of 15 

 

Creating an INSTEON Scene 

INSTEON Scenes let you activate dramatic lighting moods with the press of just one button.  INSTEON 
Scenes are very easy to set up – just link more than one INSTEON module to an ON/OFF Button Pair on 
an INSTEON Controller.  Then, when you press either the ON or the OFF Button on the INSTEON 
Controller, all of the INSTEON modules linked in the scene will respond as a group.  You can link multiple 
ICON Appliance Adapters or other INSTEON modules to multiple INSTEON Controllers. 

To add an additional ICON Appliance Adapter to a scene controlled by an ON/OFF Button Pair on an 
INSTEON Controller, simply follow the same procedure that you used for linking the first ICON Appliance 
Adapter.  See 

Linking ICON Appliance Adapter to an INSTEON Controller

, above.  To remove an ICON 

Appliance Adapter from a scene, see 

Unlinking ICON Appliance Adapter from an INSTEON Controller

TIP 

 
With some INSTEON Controllers, you can avoid having to hold a button down for 10 seconds for each 
setup step by placing the Controller in 

Scene Setup Mode

, also called 

Multilink Mode

.  Refer to your 

INSTEON Controller’s User’s Guide for detailed instructions on how to set it to Scene Setup Mode.  
The following will work for a Icon

 Tabletop Controller. 

1.  Set the Icon Tabletop Controller to Scene Setup Mode for the ON/OFF Button Pair you want to 

use for controlling the scene by pressing and holding the 

ON Button

 of the pair for 10 seconds, 

then tapping the same

 

ON Button

 

again

.  Icon Tabletop Controller’s Status LED will blink slowly. 

2.  Press and hold the black 

SET Button

 on Icon Appliance Adapter for 3 seconds.  The module’s 

Status LED will blink to confirm linking.  Icon Tabletop Controller will beep to confirm linking, and 
its Status LED will continue to blink slowly. 

3.  Continue Steps 2 and 3 for any additional INSTEON modules you want to link to the scene. 

4.  When you are finished linking INSTEON modules to the desired ON/OFF Button, complete Scene 

Setup by pressing the 

ON Button

.  Icon Tabletop Controller’s Status LED will stop blinking and 

remain steadily on.  You have about 4 minutes of inactivity before Scene Setup Mode times out 
automatically. 

Summary of Contents for 2856S3

Page 1: ...ICON Appliance Adapter Appliance Module with INSTEON Technology For model 2856S3 2856S3B ICON Appliance Adapter...

Page 2: ...6 Creating an INSTEON Scene 7 ADVANCED FEATURES OF ICON APPLIANCE ADAPTER 8 Restoring Power to ICON Appliance Adapter 8 Resetting ICON Appliance Adapter to Its Factory Default Settings 8 X10 PROGRAMMI...

Page 3: ...every INSTEON device is a two way repeater And affordable not just because of low cost but because INSTEON also works with legacy X10 devices An INSTEON home grows in value with every INSTEON device y...

Page 4: ...at least two Access Points 2 Plug ICON Appliance Adapter into an unswitched wall receptacle The green Status LED on the side will illuminate steadily 3 Plug the non dimmable device lamp you want to co...

Page 5: ...hold the ON Button of the pair for 10 seconds To confirm that it is in Linking Mode ICON Tabletop Controller s Status LED will begin blinking C ICON Keypad Dimmer Choose the ON Button you want to use...

Page 6: ...its LED B ICON Tabletop Controller Press and hold the OFF Button of the ON OFF Button Pair you used for controlling ICON Appliance Adapter for 10 seconds To confirm that it is in Unlinking Mode ICON T...

Page 7: ...old a button down for 10 seconds for each setup step by placing the Controller in Scene Setup Mode also called Multilink Mode Refer to your INSTEON Controller s User s Guide for detailed instructions...

Page 8: ...dure can be used to clear ICON Appliance Adapter s memory and restore its factory default settings This procedure will clear the unit of all INSTEON Links and any programmed X10 Primary Address 1 Befo...

Page 9: ...section for an explanation 3 Once ICON Appliance Adapter has received the X10 Address and an ON or OFF command the Status LED on ICON Appliance Adapter will stop flashing and the X10 Primary Address w...

Page 10: ...ay to overcome signals getting weaker is to increase the coverage of the mesh network by introducing more INSTEON devices It is possible that some audio video products computers power strips or other...

Page 11: ...hat you can turn on or turn off when you set the X10 Address for the product If turned on the BoosterLinc technology may interfere with INSTEON KeypadLinc 6 with Integrated 12073W 12073WB and 12073WW...

Page 12: ...not linking or responding to an INSTEON Controller The INSTEON signal may be too weak Try linking your ICON Appliance Adapter to your INSTEON Controller with both of them plugged into the same outlet...

Page 13: ...cked up A surge or excessive noise on the powerline may have glitched it If the above doesn t work perform a Factory Reset If you have tried these solutions reviewed this User s Guide and still cannot...

Page 14: ...nal INSTEON Messages Repeated Yes X10 Features X10 Primary Address 1 optional comes unassigned X10 Scene Addresses N A X10 Status Request Supported X10 Powerline Frequency 121 KHz X10 Minimum Transmit...