Position the boiler so that the tap is approximately 400mm above a draining board. Leave sufficient 
space around the unit to enable access for servicing, paying particular attention to the position of the 
top-centre fixing screw that holds the case in place. 

When mounting on wall…screw in the top two scre

ws leaving about 6mm protruding and hang the 

machine using the keyhole slots provided. Once the machine is positioned, tighten the top screws 
and insert the bottom screw. 

Do not block ventilation holes in boiler case  

 

 

b) ELECTRICAL CONNECTION 

 

The circuit should be protected by its own 13amp double-pole connection unit with flex outlet to 
BS5733, alternatively the circuit should have a means of disconnection incorporated in fixed wiring, 
having a contact separation of at least 3mm in all poles. Minimum cable size is 1.5mm

2

. The use of 

an ELCB is recommended.  

 

WARNING: This appliance must be earthed. 

Electrical installation should conform to current I.E.E. wiring regulations. 

When using fixed wiring, the bare section of earth must be sleeved to within 8mm of the end. 

Only a qualified electrician should carry out this work. 

 

BASE ENTRY OF CABLE:

 Use the cable gland. Loosen cable-gripping nut and pass cable through 

gland, leaving enough free cable to connect to terminal block. Tighten cable gland grip nut.    

    

 

DO NOT SWITCH ON UNTIL THE INSTALLATION IS COMPLETE AND THE CASE IS IN PLACE 

 
 
 
 

c) WATER CONNECTION 

NOTE: Although it will not harm the boiler, it should not be operated with water supply turned off.   

Water supply must have a pressure not exceeding 7 bar and no lower than 2 bar. (

If the mains 

water pressure is below 2 bar a fault situation could arise)   

If water pressure exceeds 7 bar a suitable water pressure reducing valve will need to be fitted 
to the water supply to bring it to a level that the machine can cope with. 

Failure to do so 

could result in the boiler overfilling

.   

 

THE MANUFACTURERS CANNOT BE HELD RESPONSIBLE FOR ANY MACHINE MALFUNCTION IF THE 
WATER  PRESSURE  IS  NOT  WITHIN  THE  RANGE  STATED.  IF  IN  DOUBT,  CONSULT  YOUR  WATER 
SUPPLY COMPANY.  

Connect to a suitable cold water drinking supply as below;  

 

Fit the 15mm push-fit coupling onto the water inlet solenoid pipe and connect to cold water 
mains supply using 15mm copper pipe.

 

NOTE

If micro-bore pipe is used instead of copper pipe, the size must be minimum OD 

3/8” 

(10mm). 

A 15mm stop valve must be fitted between the water supply and the boiler so that it can be 
isolated.        
 

Summary of Contents for DB600-WTF

Page 1: ...ee Model WMS6TF DB600 WTF Auto Fill Wall Mounted Boiler with Touch Free Dispense INSTALLATION AND USER INSTRUCTIONS Zip Water UK Ltd Trafalgar House Rash s Green Dereham Norfolk NR19 1JG Tel 0345 600...

Page 2: ...IONAL FILTER MONITOR 8 PREVENTATIVE MAINTENANCE 8 CLEANING 8 MAINTENANCE SPARES SERVICE INFORMATION 9 SERVICE WARNINGS FAULT DIAGNOSTICS 9 10 GUARANTEE 10 INTRODUCTION Dear Customer Thank you for purc...

Page 3: ...ance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Always disconnect the unit from the power supply before servicing The unit mus...

Page 4: ...age in LC Display Caution Boiling Water safety warning flashes as dispense is activated Includes easy fit spill tray bracket kit place cup on spill tray no need to hold whilst boiling water is dispens...

Page 5: ...this work BASE ENTRY OF CABLE Use the cable gland Loosen cable gripping nut and pass cable through gland leaving enough free cable to connect to terminal block Tighten cable gland grip nut DO NOT SWIT...

Page 6: ...pe must have a continuous fall and should not be longer than 300mm if a longer run is required use 22mm pipe to avoid airlocks The overflow pipe should have no more than four right angle bends and sho...

Page 7: ...run through an initial self diagnostic check before starting to fill with water screen reads NOT READY FILLING Once primed with water the boiler will begin to heat screen reads NOT READY HEATING When...

Page 8: ...sured amount into the cup teapot each time the touch free sensor is activated Top up feature At the end of the timed dispense cycle the CAUTION message will continue to flash for a further 5 seconds D...

Page 9: ...lter counter With the required filter setting selected Press hold button long push for 4 seconds to save Press hold button long push for approximately 6 seconds until display goes blank Turn machine b...

Page 10: ...lean the level sensing probes Flush with copious amounts of cold water to ensure all traces of de scaler are removed before SERVICE TECHNICAL SUPPORT SPARES To ensure your service enquiry is handled a...

Page 11: ...faulty De scale tank and level sensors Isolate machine and wait 10mins then turn back on again Reduce temperature setting Call service if fault persists R E A D Y CHANGE FILTER OPTIONAL Filter cartrid...