SCREEN MESSAGE
POSSIBLE CAUSES:
ACTION;
R E A D Y
CHECK WATER
WHITE SCREEN
•
Water turned off
•
Low
in-coming
water
pressure
•
Check water supply and
stop-cock
•
Check in-coming water is at
minimum of 2-bar
R E A D Y
CLEAN PROBES
WHITE SCREEN
•
Low-water
level
probe
scaled up
•
De-scale inside of tank and
level sensors
N O T R E A D Y
OF
RED SCREEN - FLASHING WITH
WARNING TRIANGLES
•
Normal operating probe has
scaled up
•
De-scale level sensors
N O T R E A D Y
TH
RED SCREEN
–
FLASHING WITH
WARNING TRIANGLES
•
Over-boiled
(due
to
excessive
lime-scale
in
tank).
•
Faulty Element
•
Thermistor
disconnected,
wires cut or faulty
•
Boil-dry
safety
switch
tripped or faulty
•
De-scale tank and level-
sensors
•
Isolate machine and wait
10mins, then turn back on
again.
•
Reduce temperature setting
•
Call service if fault persists.
R E A D Y
CHANGE
FILTER
(OPTIONAL)
•
Filter cartridge is
exhausted and should be
replaced as soon as
convenient
•
Replace Filter/softener
GUARANTEE
Your boiler is guaranteed for two years from date of installation.
Our guarantee includes on site labour and parts for problems caused by fault of manufacture and
component failure
with the following exclusions:
1
Problems caused by hard water and lime scale. We regret that we cannot be held responsible
for problems caused by hard water
2
Accidental damage, misuse or use not in accordance with these instructions and damage
caused by incorrect installation.
The manufacturer disclaims any liability for incidental, or consequential damages.