94
service.
4)
Front panel status indicator alarms
Description: The server is under normal operation, but system status indicator on
front control panel flashes or the red indicator is on.
Operation steps:
Please check whether all power module indicators are steadily green, if so, you can
login BMC web interface to collect logs, and contact Inspur customer service.
5)
Memory capacity incomplete
Description: Memory capacity viewed via the operating system does not correspond
with physical memory capacity.
Operation steps:
a.
Ensure all memories of correct type have been correctly installed in place.
b.
Enter BIOS setup to view memory capacity, if it could be completely identified in
BIOS setup, this may lie in the limitation on memory capacity set by the operating
system. Otherwise, please contact Inspur customer service.
6)
Keyboard and mouse are not available
Description: Neither keyboard nor mouse could be operated normally.
Operation steps:
a.
Make sure the keyboard or mouse has been connected correctly and firmly.
b.
Test other parts to verify whether it is a mouse or keyboard fault.
c.
Retest the machine via power on/off.
d.
Reboot and enter cmos or raid configuration interface to test keyboard or
mouse performance. When tested in a non-system situation, if keyboard or
mouse performance turns out to be normal, a system fault could be considered.
If keyboard or mouse fault still exists, a mainboard interface fault could be
considered, and Inspur technical hotline can be called for support.
7)
USB interface problem
Description: Unable to use devices with a USB interface.
Operation steps:
a.
Make sure the operating system on server supports USB devices.
b.
Make sure system has been installed with correct USB device driver.
c.
Power off the server, and then power on again to test.