58
2)
BIOS could carry out Dynamic and Static network settings on BMC Dedicated
management port and sharelink management port, taking Dedicated management
port as an example, to set a BMC Static IP as follows:
a.
Set the Get BMC Dedicated Parameters option to
【
Manual
】
b.
Set the Configuration Address source option to
【
Static
】
c.
Select the Station IP Address option, and press Enter, to pop up the Station
IP Address window, enter the Static IP to set manually, after configuration is
completed, press Enter to confirm, and an example is as shown in the following
figure:
d.
Select the Subnet Mask option, and press Enter, to pop up the Subnet Mask box,
enter the Subnet Mask to set manually, after configuration is completed, press
Enter to confirm, and an example is as shown in the following figure:
e.
Select the Router IP Address option, and press Enter, to pop up the Router IP
Address box, enter the Router IP Address to set manually, after configuration is
completed, press Enter to confirm, and an example is as shown in the following
figure:
f.
When Static IP configuration is done, press F10 to save and restart, BIOS will
carry out Static IP configuration for BMC.