11 Battery Replacement
If the server no longer automatically displays the correct date and time, you may
need to replace the battery that provides power to the real-time clock.
WARNING:
The computer contains an internal lithium manganese dioxide, a
vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the
battery pack is not properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose the battery to temperatures higher than 60°C (140°F).
• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire
or water.
• Replace only with the spare designated for this product.
To remove the component:
1.
Power down the server.
2.
Extend the server from the rack.
3.
Remove the access panel.
4.
Remove the full-length expansion board retainer if any full-length expansion
boards are installed.
5.
Remove the PCI riser cage.
6.
Remove the air baffle.
7.
Remove the battery.
To replace the component, reverse the removal procedure.
For more information about battery replacement or proper disposal, contact Inspur
Customer Service.