NX5760M3 Computer Blade Server
41
5.2.6
Machine alarm
If the machine alarms in startup or utilization process, please refer to the following processes
for disposal:
1. If the phenomenon occurs after you plugged some external board, it is suggested that you
pull off this device and start to test. If it is normal, it shows that your external board is incompatible
with the machine. It is suggested not to use it any more; If it is unsolved, please go on referring to
the following steps.
2. Determine the orientation of the alarm sound simply:
● If the alarm sound is from the front of the case generally followed the abnormal change of
the fault indicator, there is possibility of abnormal fan or hard disk module;
●If the alarm sound is from the rear of the case, please pay attention to check whether a
redundant power supply is configured or not and whether there is an abnormal status lamp of the
power supply module or a module without power cable or not (when power alarms, the shield
switch can be pressed to stop alarm);
● If the alarm sound is in the case, the alarm may be from mainboard , RAID card or hard disk
back plate. If it is also accompanied by no display or no power faults, there is comparatively large
possibility of bad mainboard. You can try to pull or plug RAM or clear CMOS; If the starting
self-check is normal and it alarms when testing RAID card with display of abnormal array
information, there is comparatively large possibility of RAID card alarm. There is maybe array
abnormality; When the hard disk back plate alarms, there is always abnormal status lamp of the
hard disk on the front panel which can be also used to analyze in coordination.
3. After understanding the basic information, please feedback the detail alarm information to
Inspur technical support personnel as soon as possible. We will make further analysis and
judgment and help you to solve the problem as soon as possible.
5.3
Other notices
1. This server does not support system sleep function.
2. In order to guarantee the liability of the system, it is suggested that you use the component
of the relevant model authenticated by us when expanding and equipping components.
3. Please guarantee the fine electricity utilization environment of the server, normal voltage
input and earthing condition and temperature and humidity and so on within the normal range.
4.
For special needs, when transferring the server, pay attention to avoid the vibration and
carry out in power off condition.
5.
For notices of more products, please refer to the FAQ for server in official website of Inspur:
http://www.inspur.com/support/Channel_Home/support_sv.asp