1.5 POSITIONING OF THE OVEN
The place where the oven will be installed must comply the following requirements:
•
Be protected from atmospheric agents and have an adequate air circulation;
•
Comply with regulations concerning safety at work;
•
Have a room temperature between 5 °C and 35 °C with a humidification not higher than 70%.
•
Place the oven and proceed with levelling using adjustable feet.
Keep a suitable distance at the back, in order the label of equipotential clamp is easy to see when the oven has
been installed.
The same clamp must be easy to access to install equipotential cable after the oven has been installed in compli
-
ance with our instructions.
Install the appliance in a position that allows access to the right side for installation, maintenance and technical
assistance.
ANALOGIC
1.6 TECHNICAL DATA FOR ELECTRICAL CONNECTION
CONV MANUAL HUMIDIFICATON
Model
Power loading
and voltage
no. and motor
power
Heating
power
Absorbed
current
Feed cable
section
4 x 2/3 GN
2.8 kW
220 - 240 V 1N ~
50/60 Hz
2 x 100 W
2.6 kW
4.0 A
cable included
4 x 460x340
4 x 1/1 GN
6.4 kW
380 - 415 V +3N~
50/60 Hz
2 x 100 W
6.2 kW
11.0 A
5 x 2.5 mm
2
4 x 60x40
4 x 1/1 GN
4 x 60x40
6 x 1/1 GN
7.8 kW
380 - 415 V +3N~
50/60 Hz
2 x 100 W
7.6 kW
13.5 A
5 x 2.5 mm
2
6 x 60x40
6 x 1/1 GN
6 x 60x40
10 x 1/1 GN
11.7 kW
380 - 415 V +3N~
50/60 Hz
3 x 100 W
11.4 kW
20.0 A
5 x 4.0 mm
2
10 x 60x40
10 x 1/1 GN
10 x 60x40