6: 1MKbps
Fd-13
CAN
station number
1~127 (CANlink, CANopen valid)
1
★
Fd-14
The number of CAN
frames accepted per
unit time
●
Fd-15
The maximum value
of counter the node
accepts
●
Fd-16
The maximum value
of counter the node
sends
The AF
●
Fd-17
The number of bus
drops in unit time
●
Fd-18
Number of rectifying
unit
1~99
1
★
Fd-20
DP mailing address
0~125, 0 means the broadcast address
0
★
Fd-21
DP communication
dropping coefficient
0~65535
350
☆
Fd-22
DP transferred to
CANopen bridge
mode
0: When the number of subordinate stations
configured with PLC does not match the
number of subordinate stations in the actual
network, communication errors are reported.
1: When the number of subordinate stations
configured with PLC does not match the
number of subordinate stations in the actual
network, no communication error is
reported.
0
☆
Fd-32
AF group mapping
mode switching
0: communication is not saved
1: communication is saved
0
★
Fd-33
CANopen
communication cycle
-
-
●
Fd-40
J1939
control word 1
address
0~0xFFFF
0xF000
☆
Fd-41
J1939
control word 2
address
0~0xFFFF
0xF000
☆
Fd-42
J1939 monitor word 1
address
0~0xFFFF
0xF70A
☆
Fd-43
J1939 monitor word 2
address
0~0xFFFF
0xF70B
☆
Fd-44
J1939 monitor word 3
address
0~0xFFFF
0xF710
☆
Fd-45
J1939 monitor word 4
address
0~0xFFFF
0xF709
☆
Parameter
Name
Setting range
Default
value
Change
Fd-46
J1939 message format
modification and check
0~65535
0
☆
Fd-47
ID of messeage 1
received (high 16 bit)
0~0x1FFF
0x1400
●
Fd-48
ID of messeage 1
received (low 16 bit)
0~0xFFFF
0x9183
●
Fd-49
Sending cycle 1
1~6000ms
10
●
Fd-50
ID of messeage 1 sent
(high 16 bit)
0~0x1FFF
0x1808
●
Fd-51
ID of messeage 1 sent
(low 16 bit)
0~0xFFFF
0x8391
●
Fd-52
ID of messeage 2 sent
(high 16 bit)
0~0x1FFF
0x1809
●
Fd-53
ID of messeage 2 sent
(low 16 bit)
0~0xFFFF
0x8391
●
Fd-54
ID of messeage 3 sent
(high 16 bit)
0~0x1FFF
0x180A
●
Fd-55
ID of messeage 3 sent
(low 16 bit)
0~0xFFFF
0x8391
●
Fd-56
Sending cycle 4
1~6000ms
100
●
Fd-57
ID of messeage 4 sent
(high 16 bit)
0~0x1FFF
0x180B
●
Fd-58
ID of messeage 4 sent
(low 16 bit)
0~0xFFFF
0x8391
●
Group FP Parameter management
FP-00
User password
0~65535
0
☆
FP-01
Parameter initialization
0: No operation
01: reset to factory parameters, excluding
motor parameters, encoder parameters, and
max. frequ
ency
02: clear the record information
04: back up the user's current parameters
501: restore user
’s backup parameters
502: reset to factory parameters (excluding
communication group parameters, FD
group, AF group)
0
★
FP-02
Function parameter
group display options
Units’ pl
ace: U group display options
0: not displayed
1: displayed
ten's place: A group display options
0: not displayed
1: displayed
111
☆
FP-03
Personality parameter
group display options
Units’ place: User customized parameter
group display options
0: not displayed
1: displayed
ten's place: User customized parameter
group display options
0: not displayed
1: displayed
11
☆