Fig. 7 CV800 CAN communication network
5. Programming copying
☞
Copy CV800 equipment underlying program with keyboard
Connect the SOP-20-810 keyboard to the computer via the USB extension cord and select the large
capacity mode from the keyboard display menu to see removable disk on the computer. Copy the
underlying driver .bin file required by DC-DC, inverter and PLC to keyboard SD card:
SYS/PROGRAM/path.
Fig. 8 USB
connection completed
Fig. 9 Storage path of copying file
When the CV800 driver is connected to the 24V and 540VDC power supply, keyboard may be used for
underlying upgrade of DC-DC, inverter and PLC after the three devices are searched. See Appendix A
for information on operation.
● Rooting is risky, please keep keyboard on line during the whole copying process. If power failure
occurs, the machine may be damaged.
☞
Generation and download of PLC application program
In Autoshop engineering interface, click Tool -->Generate CV800 download file, click
“OK” in the
pop-up screen, and then in the pop-up box, select the storage path and name of file to generate.
Format of file is .bin (Chinese name not supported). The copying method is same as that of underlying
programs.
PLC (with built
-
in
matched resistor)
Air
conditioning
panel
(with
built
-
in matched
resistor)
SOP
-
20
-
810 (with
built
-
in matched
resistor)
Please select USB connection mode
USB relay mode
USB mass storage mode
Return Select
•
USB mass storage mode