F2-29
synchronous motor
initial position
angle detecting
current
50%~180%
80%
☆
F2-30
Speed loop
parameter
automatic
calculation enabled
0: not enabled
1: enabled
0
★
F2-31
Expected speed
loop bandwidth
(High speed)
1.0~200.0Hz
10.0Hz
☆
F2-32
Expected speed
loop bandwidth
(Low speed)
1.0~200.0Hz
10.0Hz
☆
F2-33
Expected speed
loop bandwidth
(zero-speed)
1.0~200.0Hz
10.0Hz
☆
F2-34
Expected speed
damping ratio
0.100~65.000
1.000
☆
F2-35
System inertia
(equivalent to
startup time, unit:
s)
0.001~50.000s
Determine
specification
★
F2-36
Motor stand-alone
inertia
(kg*m2)
0.001~50.000
Determine
specification
★
F2-43
Inertia tuning and
dynamic setting
speed (unit: %,
with motor rated
power as the base
value)
0%~100%
30%
★
F2-47
Inertia tuning
enabled
0: not enabled
1: enabled
0
★
F2-48
Inertia
tuning
speed
loop
bandwidth
set
value (unit: Hz)
0.1~100.0Hz
10.0Hz
★
F2-50
Inertia tuning mode
0: acceleration and deceleration mode
1: triangular wave mode
0
★
F2-51
Inertia tuning
acceleration and
deceleration factor
(unit: 0.1)
0.1~10.0
1.0
★
F2-52
Decoupling control
enabled
0~1
0
★
Parameter
Name
Setting range
Default
value
Change
F2-53
Generation
power limiting
enabled
0: not enabled
1: enabled
0
★
F2-54
Generation
power limiting
0.0~200.0%
Determine
specification
★
Group F3 V/F control parameters
F3-00
V/F curve setting
0: straight line V/F
1: Multipoint V/F
2: square of V/F
3: 1.2
power of
V/F
4: 1.4
power of
V/F
6: 1.6
power of
V/F
8: 1.8
power of
V/F
9: kept
10: V/F
completely
divided mode
11: V/F
semi-divided mode
0
★
F3-01
Torque
magnification
0.0%: (automatic torque
magnification)
0.1%~30.0%
Determine
specification
☆
F3-02
Torque
magnification
cut-off frequency
0.00Hz~ Max. frequency
50.00Hz
★
F3-03
Multipoint V/F
frequency point 1
0.00Hz~F3-05
0.00Hz
★
F3-04
Multipoint V/F
voltage point 1
0.0%~100.0%
0.0%
★
F3-05
Multipoint V/F
frequency point 2
F3-03~F3-07
0.00Hz
★
F3-06
Multipoint V/F
voltage point 2
0.0%~100.0%
0.0%
★
F3-07
Multipoint V/F
frequency point 3
F3-05~Motor rated frequency (F1-04)
0.00Hz
★
F3-08
Multipoint V/F
voltage point 3
0.0%~100.0%
0.0%
★
F3-09
V/F torque error
compensation
gain
0.0%~200.0%
0.0%
☆
F3-10
V/F
overexcitation
gain
0~200
64
☆
F3-11
V/F oscillation
suppression gain
0~100
Determine
specification
☆
F3-12
Oscillation
suppression gain
mode
0: invalid
3:valid
3
★
0: digital setting (F3-14)
1: AI1
2: AI2