IV. OPERATION
Once the engine is running and has warned up to operating temperatures, the idle and power adjustments must
be made as the follows:
IDLE ADJUSTMENT
(Adjustment located on side of carburetor)
IN RICH
OUT LEAN
1. Timing 8
°
BTC.
2. RPM 550 – Use tachometer.
3. Adjust carburetor to ½% of 1% on CO% meter per 550 RPM.
4. Exhaust analyzer 14.5 – 14.8 gasoline scale.
5. If CO% meter or exhaust analyzer is not available, use vacuum gauge and set at highest manifold vacuum at
manufacturers idle RPM specs.
LOAD OR POWER ADJUSTMENT
(Adjustment located at under side of gas inlet)
1. Using tach with no load, make sure governor RPM are set at manufacturer specs. Return to idle.
2. Reaccelerate engine to approx. 100 to 150 rpm’s below governor and if possible, pull tilt mask back to throw
load on engine. Set power adjustment to highest RPM staying in the ½ to 1% CO reading or 14.1 to 14.5 on
exhaust analyzer scale.