![Innovatech Teerminator-2000 Operation And Maintenance Manual Download Page 22](http://html.mh-extra.com/html/innovatech/teerminator-2000/teerminator-2000_operation-and-maintenance-manual_2063663022.webp)
INNOVATECH PRODUCTS & EQUIPMENT CO., INC.
22
MAINTENANCE PROCEDURES FOR THE TERMINATOR®
Refer to the Nissan H20 Engine manual for complete maintenance instructions. When working on this
machine always take into consideration the warnings about this machine and take extra care when evaluating the
problem.
Trouble-Shooting *
THE MACHINE STOPS OR WON’T START
1.) Check all fuses under the console panel.
2.) Check the coil, wires, and ignitions system; the battery and cable connectors; and the points and
condenser.
3.) On some models check the hydraulic fluid cartridge and the red reset button. If the button is OUT, push it
IN to reset the hydraulic system.
4.) Check propane tank coupler.
5.) Wait
at least 5 minutes,
then re-start the Terminator® in the normal way (see page 23 for Start of Day or
Shift procedures)
THE ENGINE RUNS BUT THE MACHINE WON’T MOVE
1.) On some models check the hydraulic fluid diverter. Move the lever to the right or left, if it is set in idle
position.
2.) Try to drive forward (or reverse) again. If the machine won’t move, call our Customer Service
Department for assistance.
THE BATTERY GAUGE SHOWS NO CHARGE
1.) Check the alternator. Check the battery and recharge or replace it, as needed.
RUNNING HOT – Breaking in Machine – 250 degrees
1.) Check water level. Do not open radiator when hot, allow for it to cool.
2.) Check for dirt in radiator (blow out with air or water).
3.) Run with side panels off to help cool down.
4.) Run machine with hydraulic fan on at all times.
5.) Running machine at high rpm’s will cause overheating. Allow for a cool down period in your work
schedule.
6.) The room may need more air movement/circulation.
* Also see appendix for further troubleshooting information.