Points and Condensor (H20 Engines)
On older models of the Terminator® the points and condenser are part of the ignition system and need to be
replaced annually or every 200 hours running time.
Air Filter
The air filter helps prevent dust and dirt from entering the engine. Inspect the air filter before operating each
day and replace when dirty.
Hydraulic Fluid Cartridge
Inspect the hydraulic fluid cartridge regularly and replace the filter when it gets dirty. It is recommended that
the hydraulic fluid and filter be changed annually and if fluid is overheated 160
°
F – 180
°
F or higher. On 2000
models hydraulic filter should be changed every 60 hours when engine oil is changed. For every filter change you
loose approximately 1 pint of oil. So on the 8th filter change, you should add one gallon of oil.
Fuel System
STOP!
Read the propane material safety data sheets
and safety rules on pages 42-45 before proceeding.
The fuel system consists of propane tank, fuel lines, connectors, and flow control. The Terminator® is
designed to accommodate a three gallon tank, which will usually provide about three to four hours running
time. Keep a reserve tank on hand.
LPG FUEL CYLINDER REPLACEMENT PROCEDURE
1.) NO SMOKING – Do not replace fuel cylinders in areas that have a source of fuel ignition.
2.) Close cylinder valve and run engine until it stops prior to disconnecting the fuel hose from the tank.
3.) Connect fuel hose. Open valve slowly so the hose and tank pressure can equalize or the valve may slug. Should leakage occur,
close valve and have qualified personnel make repairs.
4.) Use fuel manufactured National Gas Processors association “HD-5” specification.
NOTE: THE ABOVE IS PROVIDED AS A GUIDE. FOR ADDITIONAL INFORMATION, CONSULT THE NATIONAL FIRE
PROTECTION ASSOCIATION PAMPHLET 58 FOR THE SAFE STORAGE AND HANDLING OF LIQUEFIED PETROLEUM
GASES.
NOLFF’S Carburetion, Inc. 1-800-451-7040