background image

17 

 

 

Appendix A: Limited Warranty 
 

LIMITED WARRANTY 
Innovate stands behind the quality of its products. Innovate makes the following warranty to 
purchasers of its products: All new Innovate products carry a one year warranty from the date of 
purchase. If proof of purchase cannot be provided, warranty will be determined by date of 
manufacture. 

When Warranty Void 
This warranty shall terminate and Innovate shall have no obligation pursuant to it if (i) your 
Innovate product has been modified or repaired in a manner not previously authorized by 
Innovate in writing, (ii) the identification markings on your Innovate product have been removed, 
defaced, or altered; (iii) your Innovate product was subjected to accident, abuse, shipping 
damage, or improper use; (iv) your Innovate product was not used or configured as specified in 
the product manual; or (v) your Innovate product was subjected to operating conditions more 
severe than those specified in the product manual. 

Exclusions From This Warranty 

Oxygen Sensors are excluded from this warranty.

 

Repairs Under This Warranty 
In the unlikely event that your Innovate hardware product should prove defective during the 
warranty period, contact Innovate Customer Support at 
http://www.innovatemotorsports.com/rma_form.php for a return material authorization (RMA). 
Products returned for service must be securely packed to prevent damage and shipped charges 
pre paid, along with proof of purchase and the return material authorization number, to the 
Innovate repair location as instructed by Customer Service. Innovate within a reasonable 
amount of time from its receipt of your product so shipped, will ship to you, at its option, the 
repaired product or a new or reconditioned product of comparable or greater specified 
functionality. All repaired or replacement products shall be warranted for the remainder of the 
original product warranty.  

Disclaimer 
INNOVATE MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO 
YOUR INNOVATE PRODUCT OTHER THAN THE LIMITED WARRANTY SET FORTH ABOVE. 
No Innovate dealer, agent, or employee is authorized to make any modification, extension, or 
addition to this warranty, unless enforceable or unlawful under applicable law, INNOVATE 
DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF 
MERCHANTABILITY, NONINFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE, 
AND THE LIABILITY OF INNOVATE, IF ANY, FOR DAMAGES RELATING TO ANY 
ALLEGEDLY DEFECTIVE PRODUCT SHALL UNDER ANY TORT, CONTRACT, OR OTHER 
LEGAL THEORY BE LIMITED TO THE ACTUAL PRICE PAID FOR SUCH PRODUCT AND 
SHALL IN NO EVENT INCLUDE INCIDENTAL, CONSEQUENTIAL, SPECIAL, OR INDIRECT 
DAMAGES OF ANY KIND EVEN IF INNOVATE IS AWARE OF THE POSSIBILITY OF SUCH 
DAMAGES. Some states do not allow limitations on how long an implied warranty lasts or the 
exclusion or limitation of incidental or consequential damages, so the above limitations or 
exclusions may not apply to you. 

 

 

Summary of Contents for PSN-1

Page 1: ... Wideband Oxygen Sensor Setup 7 2 6 1 Sensor Calibration 8 2 6 2 Calibration Schedule 9 PSN 1 Setup 10 3 3 1 Entering Setup Configuration 10 3 1 1 Configuration using PSN 1 s interface buttons 10 3 1 2 Configuration using the LM Programmer software 10 3 2 Display Settings Gauge Abbreviations 11 3 3 RPM Settings Gauge Abbreviations 12 3 4 Nitrous Safety Settings Gauge Abbreviations 12 Logworks 3 LM...

Page 2: ...an be cycled through on the main screen with the left and right interface buttons It can be configured to display A F or bottle pressure as primary channels or both A F and bottle pressure in both the primary and secondary channel viewports 2 Status or Error display The upper right hand viewport of the PSN 1 is reserved to display the PowerSafe status or any error codes that might be present O2 er...

Page 3: ...en the PSN 1 will display Valet 4 Shift Light Illuminates when the trigger shift RPM is reached 1 1 Changing the PSN 1 s gauge face and or bezel 1 Lay the PSN 1 face down and remove the three 2 phillips screws from the outside rim of the back plate 2 3 Configure the gauge as desired by changing the gauge face and or bezel 4 Make sure every piece is positioned correctly using the locating tab and r...

Page 4: ...e BLACK wire should be grounded to a solid ground source The best possible ground source would be the battery ground post If other Innovate Motorsports devices are going to be daisy chained along with the PSN 1 it is recommended that all devices be connected to a single ground point ideally the battery ground post 3 Connect the WHITE wire to a headlight power wire a wire that goes hot with 12V whe...

Page 5: ...running a multi spark i e MSD 6AL Note A tach signal can not be acquired from the negative lead of the coil on vehicles running CDI ignitions For these applications use the negative lead of an injector or a tach adapter if available for your model ignition 2 1 1 Single Innovate Device Relay Wiring Instructions The relay diagram below is intended for use to power the gauge it is not for the PowerSa...

Page 6: ...ange Once in the programmed RPM range the unit will display Armed and the relay will be closed While the PSN 1 is Armed nitrous cuts will occur if either the Air Fuel ratio and or bottle pressure user defined thresholds are met 1 Disconnect the battery negative ground lead 2 Locate the trigger lead to the relay s originating from the arming switch Find a location that has enough wire length on bot...

Page 7: ...ks best 2 5 Wideband Oxygen Sensor Setup 2 6 Sensor Placement Optimum bung placement will vary from application to application but using the guideline below will ensure the longest sensor life with the most accurate readings Using a bung is the preferred method for mounting the oxygen sensor in all applications Weld the bung at least 24 inches downstream of the exhaust port outlet after the collec...

Page 8: ...pre warm before starting the engine will increase the possibility of damaging the sensor from shock cooling The maximum temperature of the sensor at the bung the sensor mounting location should not exceed 500 o C or 900 o F If these temperatures are exceeded in your application you should install the Innovate Motorsports HBX 1 heat sink bung extender p n 3729 As the O2 sensor measures the oxygen c...

Page 9: ... display will switch from O2 HTR and quickly flash O2 CAL indicating that the sensor is being calibrated The calibration procedure has completed and the system is now ready for use Important You can disconnect and reconnect the sensor and sensor cable for installation without losing your calibration However if you power up the PSN 1 without a sensor connected your calibration will be reset see ste...

Page 10: ...Once in setup mode pressing and HOLDING both interface buttons together will move you to the main screen The gauge will revert back to the main screen if no there have been no button presses for 15 seconds 3 1 2 Configuration using the LM Programmer software Refer to chapter 4 Logworks 3 LM Programmer Software Package to gain access to the software 1 Connect the OUT port of the PSN 1 to the provid...

Page 11: ...g is PSI 2 Wideband O2 Units WB O2 Units Allows the gauge to display O2 units in either AFR or Lambda Default setting is AFR 3 Enable Wideband O2 WB O2 State Allows the wideband to be disabled or enabled Also indicates the sensor type used sensor type can only be changed by connecting the PSN 1 to LM Programmer Default setting is O2 enabled NOTE If the wideband is disabled the O2 sensor should be ...

Page 12: ...desired minimum bottle pressure When the safety Bottle Pressure is triggered the PSN 1 will display P Cut on the upper right hand corner viewport and the relay will interrupt all nitrous functions Default setting is 950 PSI 3 Nitrous Cut by AFR This is a safety trigger to interrupt nitrous function by a defined AFR There are two setup parameters to trigger this safely cut Min RPM AFR RPM Min and A...

Page 13: ...mer manuals and tools can then be located by navigating through Start Programs LogWorks3 4 2 LM Programmer LM Programmer is used to configure settings on your PSN 1 1 Connect the OUT port of the PSN 1 to the provided serial programming cable Connect the other end of the serial programming cable to your computer If your computer does not have a serial port you can purchase a USB to Serial adapter f...

Page 14: ...vanced button allows the user to set the analog out update speed and the voltage output during sensor Warm up and error conditions The factory defaults of the analog outputs update 1 12 of a second The default voltage output is set at 0 volts for both the Warm up and error conditions When setting the PSN 1 to the slower response speed settings the measured mixture data will be averaged over the re...

Page 15: ... is multi sensor compatible with the Bosch LSU 4 2 and 4 9 sensors In order to go from one sensor type to another the PSN 1 must be connected to the LM Programmer software and the appropriate sensor type must be selected The Sensor Type to use setting can be found in the Info tab when LM Programmer connects to the PSN 1 Once the sensor type is changed a sensor calibration must be performed with th...

Page 16: ...your computer If your computer does not have a serial port you can purchase a USB to Serial adapter from Innovate Motorsports P N 3733 or use any USB to serial adaptor that includes drivers Make sure that nothing is connected to the IN port of the PSN 1 Power up the PSN 1 2 Launch LogWorks The LogWorks application can be launched from Start Programs LogWorks3 Logworks3 from the Windows task bar 3 ...

Page 17: ...to prevent damage and shipped charges pre paid along with proof of purchase and the return material authorization number to the Innovate repair location as instructed by Customer Service Innovate within a reasonable amount of time from its receipt of your product so shipped will ship to you at its option the repaired product or a new or reconditioned product of comparable or greater specified func...

Page 18: ...or calibration 3 Replace sensor cable 4 Replace sensor Error 5 Reference cell circuit shorted 1 Short in sensor cable 2 Short in sensor 1 Replace sensor cable 2 Replace sensor Error 6 Reference cell circuit open 1 Damaged sensor cable or sensor 2 Connectors not fully seated 1 Verify that all sensor connectors are fully seated and locked into position 2 Replace sensor 3 Replace sensor cable Error 7...