16
4.3
Logging data from your PSN-1 with LogWorks
Logworks is an invaluable tool to help setup your PSN-1. The PSN-1 has four
channels of sensor data built in for the tuning of not only your desired boost
levels, but also a safe operating air fuel ratio for your engine. These channels
are:
1. Wideband O2: Units in AFR or Lambda
2. RPM
3. Nitrous Bottle Pressure
4. Relay State
1.
Connect the OUT port of the PSN-1 to the provided serial
programming cable. Connect the other end of the serial
programming cable to your computer. If your computer does not
have a serial port, you can purchase a USB to Serial adapter from
Innovate Motorsports (P/N 3733) or use any USB to serial adaptor
that includes drivers. Make sure that nothing is connected to the IN
port of the PSN-1. Power up the PSN-1.
2.
Launch LogWorks. The LogWorks application can be launched from
Start->Programs->LogWorks3->Logworks3
from the Windows task
bar.
3.
Once LogWorks launches go to
File->Connect.
You will be prompted
to connect to the serial COM port. Select the COM port the device is
connected to and then click Connect.
4.
You will now see live data streaming from the PSN-1.
5. To start recording go to File->New Realtime Log
or, in the Toolbar,
click on the
Tool.