background image

10 

 

 PSN-1 

Setup 

3

3.1 

Entering Setup Configuration 

 
The PSN-1 can be configured directly from the gauge itself or by connecting 
it to a computer with the LM Programmer software.  

3.1.1 

Configuration using PSN-1’s interface buttons 

1. 

From the main screen,  press and HOLD the left interface button to 
put the gauge in setup mode 

2. 

Pressing either the left or right interface buttons will allow you to 
cycle through the 10 different setup parameters in the menu. 

3. 

Once the desired setup parameter is displayed, press and HOLD the 
left interface button to make a change. Once the parameter’s 
configuration has been entered it will start flashing.  

4. 

Make changes by using the left or right interface buttons.  

5. 

Once in setup mode, pressing and HOLDING both interface buttons 
together will move you to the main screen. The gauge will revert back 
to the main screen if no there have been no button presses for 15 
seconds. 

 

3.1.2 

Configuration using the LM Programmer software 

Refer to chapter 4, Logworks 3 & LM Programmer Software Package to gain 
access to the software.   
 

1. 

Connect the OUT port of the PSN-1 to the provided serial 
programming cable.  Connect the other end of the serial 
programming cable to your computer.  If your computer does not 
have a serial port, you can purchase a USB to Serial adapter from 
Innovate Motorsports (P/N 3733) or use any USB to serial adaptor 
that includes drivers. Make sure that nothing is connected to the IN 
port of the PSN-1 

2. 

Power up the PSN-1. 

3. 

Launch 

LM Programmer.

  The LM Programmer application can be 

launched from 

Start->Programs->LogWorks3->LM Programmer

 from 

the Windows task bar. 

Summary of Contents for PSN-1

Page 1: ... Wideband Oxygen Sensor Setup 7 2 6 1 Sensor Calibration 8 2 6 2 Calibration Schedule 9 PSN 1 Setup 10 3 3 1 Entering Setup Configuration 10 3 1 1 Configuration using PSN 1 s interface buttons 10 3 1 2 Configuration using the LM Programmer software 10 3 2 Display Settings Gauge Abbreviations 11 3 3 RPM Settings Gauge Abbreviations 12 3 4 Nitrous Safety Settings Gauge Abbreviations 12 Logworks 3 LM...

Page 2: ...an be cycled through on the main screen with the left and right interface buttons It can be configured to display A F or bottle pressure as primary channels or both A F and bottle pressure in both the primary and secondary channel viewports 2 Status or Error display The upper right hand viewport of the PSN 1 is reserved to display the PowerSafe status or any error codes that might be present O2 er...

Page 3: ...en the PSN 1 will display Valet 4 Shift Light Illuminates when the trigger shift RPM is reached 1 1 Changing the PSN 1 s gauge face and or bezel 1 Lay the PSN 1 face down and remove the three 2 phillips screws from the outside rim of the back plate 2 3 Configure the gauge as desired by changing the gauge face and or bezel 4 Make sure every piece is positioned correctly using the locating tab and r...

Page 4: ...e BLACK wire should be grounded to a solid ground source The best possible ground source would be the battery ground post If other Innovate Motorsports devices are going to be daisy chained along with the PSN 1 it is recommended that all devices be connected to a single ground point ideally the battery ground post 3 Connect the WHITE wire to a headlight power wire a wire that goes hot with 12V whe...

Page 5: ...running a multi spark i e MSD 6AL Note A tach signal can not be acquired from the negative lead of the coil on vehicles running CDI ignitions For these applications use the negative lead of an injector or a tach adapter if available for your model ignition 2 1 1 Single Innovate Device Relay Wiring Instructions The relay diagram below is intended for use to power the gauge it is not for the PowerSa...

Page 6: ...ange Once in the programmed RPM range the unit will display Armed and the relay will be closed While the PSN 1 is Armed nitrous cuts will occur if either the Air Fuel ratio and or bottle pressure user defined thresholds are met 1 Disconnect the battery negative ground lead 2 Locate the trigger lead to the relay s originating from the arming switch Find a location that has enough wire length on bot...

Page 7: ...ks best 2 5 Wideband Oxygen Sensor Setup 2 6 Sensor Placement Optimum bung placement will vary from application to application but using the guideline below will ensure the longest sensor life with the most accurate readings Using a bung is the preferred method for mounting the oxygen sensor in all applications Weld the bung at least 24 inches downstream of the exhaust port outlet after the collec...

Page 8: ...pre warm before starting the engine will increase the possibility of damaging the sensor from shock cooling The maximum temperature of the sensor at the bung the sensor mounting location should not exceed 500 o C or 900 o F If these temperatures are exceeded in your application you should install the Innovate Motorsports HBX 1 heat sink bung extender p n 3729 As the O2 sensor measures the oxygen c...

Page 9: ... display will switch from O2 HTR and quickly flash O2 CAL indicating that the sensor is being calibrated The calibration procedure has completed and the system is now ready for use Important You can disconnect and reconnect the sensor and sensor cable for installation without losing your calibration However if you power up the PSN 1 without a sensor connected your calibration will be reset see ste...

Page 10: ...Once in setup mode pressing and HOLDING both interface buttons together will move you to the main screen The gauge will revert back to the main screen if no there have been no button presses for 15 seconds 3 1 2 Configuration using the LM Programmer software Refer to chapter 4 Logworks 3 LM Programmer Software Package to gain access to the software 1 Connect the OUT port of the PSN 1 to the provid...

Page 11: ...g is PSI 2 Wideband O2 Units WB O2 Units Allows the gauge to display O2 units in either AFR or Lambda Default setting is AFR 3 Enable Wideband O2 WB O2 State Allows the wideband to be disabled or enabled Also indicates the sensor type used sensor type can only be changed by connecting the PSN 1 to LM Programmer Default setting is O2 enabled NOTE If the wideband is disabled the O2 sensor should be ...

Page 12: ...desired minimum bottle pressure When the safety Bottle Pressure is triggered the PSN 1 will display P Cut on the upper right hand corner viewport and the relay will interrupt all nitrous functions Default setting is 950 PSI 3 Nitrous Cut by AFR This is a safety trigger to interrupt nitrous function by a defined AFR There are two setup parameters to trigger this safely cut Min RPM AFR RPM Min and A...

Page 13: ...mer manuals and tools can then be located by navigating through Start Programs LogWorks3 4 2 LM Programmer LM Programmer is used to configure settings on your PSN 1 1 Connect the OUT port of the PSN 1 to the provided serial programming cable Connect the other end of the serial programming cable to your computer If your computer does not have a serial port you can purchase a USB to Serial adapter f...

Page 14: ...vanced button allows the user to set the analog out update speed and the voltage output during sensor Warm up and error conditions The factory defaults of the analog outputs update 1 12 of a second The default voltage output is set at 0 volts for both the Warm up and error conditions When setting the PSN 1 to the slower response speed settings the measured mixture data will be averaged over the re...

Page 15: ... is multi sensor compatible with the Bosch LSU 4 2 and 4 9 sensors In order to go from one sensor type to another the PSN 1 must be connected to the LM Programmer software and the appropriate sensor type must be selected The Sensor Type to use setting can be found in the Info tab when LM Programmer connects to the PSN 1 Once the sensor type is changed a sensor calibration must be performed with th...

Page 16: ...your computer If your computer does not have a serial port you can purchase a USB to Serial adapter from Innovate Motorsports P N 3733 or use any USB to serial adaptor that includes drivers Make sure that nothing is connected to the IN port of the PSN 1 Power up the PSN 1 2 Launch LogWorks The LogWorks application can be launched from Start Programs LogWorks3 Logworks3 from the Windows task bar 3 ...

Page 17: ...to prevent damage and shipped charges pre paid along with proof of purchase and the return material authorization number to the Innovate repair location as instructed by Customer Service Innovate within a reasonable amount of time from its receipt of your product so shipped will ship to you at its option the repaired product or a new or reconditioned product of comparable or greater specified func...

Page 18: ...or calibration 3 Replace sensor cable 4 Replace sensor Error 5 Reference cell circuit shorted 1 Short in sensor cable 2 Short in sensor 1 Replace sensor cable 2 Replace sensor Error 6 Reference cell circuit open 1 Damaged sensor cable or sensor 2 Connectors not fully seated 1 Verify that all sensor connectors are fully seated and locked into position 2 Replace sensor 3 Replace sensor cable Error 7...

Reviews: