Innova Air Compact 4M Instruction Manual Download Page 7

Instruction manual 

Pag. 7 of 28 

Date 2021-07-27 

 

 

 

 

4.0 GENERAL NOTICES 

 

4.1.1  SA F ET Y  M E  A S U R E S 

 

This instruction manual is an integral part of the appliance and therefore must be kept with care and must 
ALWAYS accompany the appliance even in case of its sale to another owner or user or to a transfer to 
another plant. In case it is damaged or lost, request another copy from the Technical Service of the area. 

 

During all operations on the device it is necessary to observe the precautions specified in this manual and 
on the labels attached to the appliance, as well as all the precautions suggested by common sense, and 
the safety regulations currents at the place of installation. 

 

Please read this manual carefully before proceeding with any operation (installation, maintenance, use) 
and follow scrupulously the instructions contained in the individual chapters. Failing to comply with the 
instructions contained in this manual and use the appliance outside the operating limits specified will void 
the warranty. 
Make known these instructions to all staff interested at the machine. 

 

The manufacturer assumes no responsibility for damage to people or property arising from the failure to 
compliance with the rules contained in this booklet. 

 

In case of replacement of parts, use only original spare parts. 

 

You should always use personal protective elements to perform actions on the devices. 

 

The installation and maintenance of air conditioning equipment may be dangerous because within these 
devices there are pressurized refrigerant gas and electrical devices. Therefore the installation, initial start -up 
and subsequent maintenance must be carried out by authorized and qualified personnel only. 

 

In case of leakage of refrigerant fluid, it is mandatory to ventilate the room, considering also that refrigerant 
fluid when exposed to flame produces toxic gas. 

 

When refilling the system, after eventual leakage and repair, be sure that inside the refrigerant circuit does 
not enter any substance, such as air, other than the specified refrigerant (R410A). The presence of air or 
other foreign substances in the circuit of refrigerant may cause an abnormal increase of pressure or 
breakage, resulting in personal injury. 

 

In the case of water spills from seawater circuit, switch off immediately compressor and source-side pump 
and shut off Manual Valves in order to stop the flow. 

 

If the unit is not in use during cold weather, drain all hydraulic circuits connected to the unit, as well as the seawater 
condenser, to prevent freezing. 

 

Some parts of the appliance produce heat during operation. The room installation must ensure adequate 
ventilation and proper heat dissipation. 

 

4.1.2  P R O H I B I T I O N S 

We remember that the use of products that use electricity and water involves the observance of some 
basic safety rules such as: 

 

It is forbidden the use by children and unassisted disabled  people. 

 

Do not touch the appliance when barefoot or with wet or damp parts of the body. 

Summary of Contents for Air Compact 4M

Page 1: ...Via I Maggio 8 38089 STORO TN Italia Tel 39 0465 670104 Web site www innovaenergie com eMail info innovaenergie com WATER TO AIR S E L F C O N T AI NED UNITS DC INVERTER Technology Air Compact 4M Air...

Page 2: ...4 1 1 SAFETY MEASURES 7 4 1 2 PROHIBITIONS 7 4 1 3 RESPONSIBILITY 8 5 0 INSTALLATION 8 5 1 1 HYDRAULIC CONNECTIONS 10 5 1 2 AIR DUCTS CONNECTION 13 5 1 3 ELECTRICAL CONNECTION 16 5 1 4 THERMOSTAT BULB...

Page 3: ...en prepared with the aim to give you all the explanations to be able to properly install the unit SELF CONTAINED Air Compact and to better manage the device Improper installation procedures can result...

Page 4: ...ING Lift the unit avoiding to catch it in sensitive parts such as tubing and air adapters When the load is lifted off the ground stay away from below and surrounding area During transport operations r...

Page 5: ...temperature and relative humidity fluctuations By using unit INVERTER Brushless DC it is possible install on board a smaller power generator than the one necessary for operating a traditional ON OFF a...

Page 6: ...rmal load and it allows to keep the air temperature stable always near the Set Point value w ithout sharp fluctuations Thanks to the Brushless DC motor and to the sound absorbing insulation silence is...

Page 7: ...evices The installation and maintenance of air conditioning equipment may be dangerous because within these devices there are pressurized refrigerant gas and electrical devices Therefore the installat...

Page 8: ...the mains by putting the system power switch to OFF position Do not dispose abandon or leave within the reach of children the packaging material because it can be a potential source of danger It is fo...

Page 9: ...ion of the appliance raise the manufacturer from any form of guarantee and liability for damage caused to people animals or things WARNING The appliance must be installed in a protected area and in su...

Page 10: ...1 HY DRAUL I C CO NNE CT I O NS The following is a summary of how to install the unit on a source circuit and at the outlet CORRECT SYSTEM INSTALLATION The minimum nominal diameter of the connecting p...

Page 11: ...21 07 27 SOURCE CIRCUIT Installing electric pump The source side pump is needed to circulate the amount of water required in the heat exchanger If necessary the system can also work in a closed circui...

Page 12: ...operations it is essential that each hydraulic connection is provided with the respective shut off valve DRAIN 5 1 2 AI R DUCT S CO NNE CT I O N IMPORTANT Both outlet fittings can be ducted allowing t...

Page 13: ...at its maximum performance with one duct only using the size 150mm to do that the horizontal 125 mm flange must be dismounted and substituted with the 150mm flange supplied with the unit The top outle...

Page 14: ...uction area of the unit Air distribution The system needs a correct air flow in order to work efficiently It is therefore important to get the correct distribution without bottlenecks by maintaining t...

Page 15: ...environment through an air gas exchanger equipped with aluminum fins having small pitch A filter must be located upstream the exchanger in order to protect it from dust NOTE the filter must be easy re...

Page 16: ...les respecting the data provided in chapter Technical data and it shall be properly grounded FIXING The electrical box is delivered fixed on the self contained unit however in case of limited space du...

Page 17: ...te 2021 07 27 5 1 4 TH E R M O S TA T BUL BS A temperature sensor bulb is fixed to the drain pan through a bracket and located near the unit air suction The main temperature sensor working sensor is l...

Page 18: ...thermostat must be installed in a proper position away from direct heat source The set point temperature and real value are shown on the thermostat display display 6 a liu c n 1o fi i i a lr e f Jl _...

Page 19: ...Instruction manual Pag 19 of 28 Date 2021 07 27...

Page 20: ...due to poor water circulation on the source side or too low water temperature below 5 C Please check the seawater flow first as specified above 7 0 WORKING LIMITS The unit operates correctly within th...

Page 21: ...ons could lead to an abnormal operating condition that could cause injury or damage to any equipment or other property additional precautions must be designed into the control system Other devices lim...

Page 22: ...end customer Transportation damages This should be claimed directly with the forwarding company Repair costs due to failure of INNOVA equipment due to negligence improper installation or non respectin...

Page 23: ...ler Refers to pages containing instructions or information for the installer S Service for the CUSTOMER TECHNICAL ASSISTANCE SERVICE installer Safety pictograms Warning The operation described may cau...

Page 24: ...1 11 6 Activation 11 11 7 Heating air conditioning mode setting 11 11 8 Stand by 11 11 9 Temperature selection 11 11 10 Automatic operation 12 11 11 Medium speed fan operation 12 11 12 Minimum fan spe...

Page 25: ...ode 11 2 Display 11 1 Electronic smart touch panel with room probe Touch control panel is an electronic thermostat with a room temperature probe for controlling air conditioning units both On Off and...

Page 26: ...Instruction manual Pag 25 of 28 Date 2021 07 27...

Page 27: ...N Stand by key From off to on Select one of the 4 operating modes by pressing the relative key Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode betwee...

Page 28: ...other degree after two hours in cooling mode Key Operation Display Press and hold the Max Operation key The function being activated is indicated by the relevant symbol appearing on thedisplay In this...

Page 29: ...justed in a range from 9 to 12 K in intervals of 0 1 C Use this adjustment with care and only after having actually detected a discrepancy compared with the actual room temperature using a reliabledev...

Page 30: ..._____ _ _____ _ _____ _ _ _____ _ _____ _ _____ _ _____ _ _____ _ _____ _ _____ _ _ _____ _ _____ _ _____ _ _____ _ _____ _ _____ _ _____ _ _ _____ _ _____ _ _____ _ _____ _ Date 2018 11 27 Instructio...

Reviews: