InnoMedia HG8328-1W Administrative Guide
Page 47
Copyright © 2019 InnoMedia. All rights reserved.
Figure 40. Configuring EMS Server Information
Field Name
Description
Enable EMS
This enables the EMS feature.
Device Type (0-
254)
This is the device type configured on the
EMS Server, so that a user of the EMS server
will see the device by name (such as 8328-1)
in the device list. The type is also important
for what options/features will be seen when
a device is queried by the EMS.
EMS Server
The IP or FQDN address of the EMS Server
and port. Default is to use port 5200 for
connection to the EMS server.
Password
The authentication password to connect to
the EMS server.
Local EMS Port
The port number used at the MTA device in
order to connect to EMS server.
Region ID
The Region to which the device is assigned.
This is a number value that has to be
entered, so an example of region
configuration might be based on Area
Codes. Another example might be time
zones. When the EMS Server is set up,
careful consideration should be given to
how the regions are defined.
Heartbeat type
The MTA will send a heartbeat to the EMS
Server to let it know it is up and running. A
Data Tunnel between the EMS and MTA is
used, and this can be encrypted or not,
depending on the Option type chosen.
Below are the current Heartbeat types: