InnoMedia HG8328-1W Administrative Guide
Page 48
Copyright © 2019 InnoMedia. All rights reserved.
2 = Plain text tunnel formatted.
3 = Encrypted text using a shared secret key
4 = Plain text and carrying SIP registration
status
5= Encrypted text and carrying SIP
registration status
Heartbeat interval
The interval at which to send heartbeat
packets to the EMS server, in seconds. The
MTA uses this HB interval unless instructed
by EMS for a new HB interval
5.8
Trace Log
5.8.1
Trace Log Setting
Configure the MTA device to display debugging messages according to the trace level parameters. Note:
Trace Level “LOG_DEBUG” will have a significant performance impact on the MTA device. It is recommended
to use this feature only when debugging is needed.
An example is described as follows.
On WEB GUI:
1.
Check “Enable Trace Log”
2.
Trace Level menu, choose “LOG_DEBUG”
3.
Check “Trace Verbose”
4.
Configure “Trace Channel” to be “0” to monitor all ports of the system.
5.
Check whatever items to be monitored from the “Trace Group Setting” table.