1. Safety Precautions 

 

Ensure the product using within the specification.   

 

 

 

 

 

Do  not  touch  the  terminals  at  least  while  power  is  being  supplied.  Doing  so  may 

occasionally result in injury due to electric shock. 

 

Do  not  allow  pieces  of  metal,  wire  clippings,  or  fine  metallic  shaving  or  filings  from 
installation  to  enter  the  product.  Doing  so  may  occasionally  result  in  electric  shock, 

fire, or malfunction. 

 

 

Do  not  use  the  product  where  subject  to  flammable  or  explosive  gas.  Otherwise, 

injury from explosion may occasionally occur. 

 

 

 

 

 

Never  disassemble,  modify  or  repair  the  product  or  touch  any  of  the  internal  parts. 

Electric Shock, fire, or malfunction may occasionally occur. 

 

 

 

 

If the output relays are used past their life expectancy, contact fusing or burning may 

occasionally  occur.  Always  consider  the  application  conditions  and  use  the  output 
relays  within  their  rated  load  and  electrical  life  expectancy.  The  life  expectancy  of 

output relays varies considerably with the output load and switch conditions. 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

Summary of Contents for ITC-106

Page 1: ...prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject...

Page 2: ...nel Instruction 6 6 Setting Parameters 7 6 1 Sensor Type and Measuring Range 7 6 2 Operation Guide 7 6 21 Boot screen display 7 6 22 Enter the settings menu 7 6 23 Sensor Input Type Setting 8 6 24 Out...

Page 3: ...ric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur Never disassemble modify or repair the product o...

Page 4: ...ccuracy 0 2 FS 0 1 C F 1000 C F 1 C F 1000 C F Sampling Period 0 5 second Temperature Compensation 0 50 C 32 122 F Control Output Relay Output AC 250V 3A resistive load Voltage Output for driving SSR...

Page 5: ...when there are two or more temperature controllers installed 4 Wiring Diagram 2 wires sensor 3 wires sensor Thermocouple Output Relay Output Voltage Power Connection 9 and 10 terminals are for power...

Page 6: ...rapidly by keeping press this button DOWN Button when setting the value pressing the down button can be decrease the value that would be reduced rapidly by keeping press this button SHIFT Button when...

Page 7: ...750 F E 0 1000 C 0 1800 F J 0 1000 C 0 1800 F B 0 1800 C 0 3200 F N 0 1000 C 0 1800 F Remarks The faulty input sensor is the K type If select the wrong input sensor the measuring temperature will be i...

Page 8: ...and activate the alarm The exceeding temperature value is related to the heating system but it will return to normal after finished the self tuning If the temperature control requirement is undemandin...

Page 9: ...ITC 106 User Manual Inkbird Tech Co Ltd www ink bird com 9...

Page 10: ...ndition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or...