5. 

Panel Instruction

 

 

 PV Displaying Screen: 

Displaying the measuring value or the setting parameters. 

 

 SV Displaying Screen: 

Displaying the setting value or the set parameters readout. 

 

 Working Indicator Light 

        OUT: Control Output Indicating 

        ALM: Alarm Output Indicating 

        RUN: Manual Operation Indicating 

 

  UP  Button: 

when setting the value, pressing the up button can be increase the value 

that would be added rapidly by keeping press this button. 

 

 DOWN Button: 

when setting the value, pressing the down button can be decrease the 

value that would be reduced rapidly by keeping press this button. 

 

 SHIFT Button: 

when setting the value or parameters,  

        A, pressing this button to switch to the required value position. 
        B, Pressing this button can be shift to the submenu from the main menu. 

        C,  Pressing  this  button  can  be  freely  switch  to  another  mode  from  manual  or  the                                                   

automatic operation. 

 

  SET  Button: 

Pressing  this  button  can  read  the  value  of  control  output  and  the  set 

temperature.  Hold  and  press  this  SET  button  for  3s  or  more  can  be  enter  into  the 

parameters settings mode. 

 

 

Summary of Contents for ITC-106

Page 1: ...prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject...

Page 2: ...nel Instruction 6 6 Setting Parameters 7 6 1 Sensor Type and Measuring Range 7 6 2 Operation Guide 7 6 21 Boot screen display 7 6 22 Enter the settings menu 7 6 23 Sensor Input Type Setting 8 6 24 Out...

Page 3: ...ric shock fire or malfunction Do not use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur Never disassemble modify or repair the product o...

Page 4: ...ccuracy 0 2 FS 0 1 C F 1000 C F 1 C F 1000 C F Sampling Period 0 5 second Temperature Compensation 0 50 C 32 122 F Control Output Relay Output AC 250V 3A resistive load Voltage Output for driving SSR...

Page 5: ...when there are two or more temperature controllers installed 4 Wiring Diagram 2 wires sensor 3 wires sensor Thermocouple Output Relay Output Voltage Power Connection 9 and 10 terminals are for power...

Page 6: ...rapidly by keeping press this button DOWN Button when setting the value pressing the down button can be decrease the value that would be reduced rapidly by keeping press this button SHIFT Button when...

Page 7: ...750 F E 0 1000 C 0 1800 F J 0 1000 C 0 1800 F B 0 1800 C 0 3200 F N 0 1000 C 0 1800 F Remarks The faulty input sensor is the K type If select the wrong input sensor the measuring temperature will be i...

Page 8: ...and activate the alarm The exceeding temperature value is related to the heating system but it will return to normal after finished the self tuning If the temperature control requirement is undemandin...

Page 9: ...ITC 106 User Manual Inkbird Tech Co Ltd www ink bird com 9...

Page 10: ...ndition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or...

Reviews: