Summary of Contents for IVM-TOUCH

Page 1: ...G ...

Page 2: ...oduced by Fancom For the latest information about product installation and operation please contact the customer service dept and or the technical service dept of the Fancom concerned In spite of the care taken when compiling this manual if you should discover any errors please inform Fancom B V in writing Fancom B V PO Box 7131 5980 AC Panningen the Netherlands Copyright 2019 Fancom B V Panningen...

Page 3: ...uch 6 3 5 Test the IVM Touch 12 4 Using the IVM Touch 13 4 1 Main parts 13 4 2 Working with the IVM Touch 14 4 3 Daily management 15 4 4 Maintenance 16 4 5 Alarms 16 4 6 Extra possibilites 17 5 Technical specifications 18 5 1 Interior IVM Touch 24Vac 19 5 2 Interior IVM Touch 230Vac 21 6 Appendixes 24 6 1 Appendix Connection diagram TRIAC 6A 24 6 2 Appendix Connection diagram TRIAC 10A 25 6 3 Appe...

Page 4: ...ding recommendations and additional information Warning indicating damage to the product if you do not follow procedures carefully Warning indicating danger to humans or animals Electrical shock hazard Danger to humans and animals Example of a practical application of the described functionality Calculation example For any questions and support please contact the local Fancom Sales Service Center ...

Page 5: ... This paragraph contains a number of general safety instructions The installation of the device and remedying of any malfunctions should be performed by a certified electrical installer according to the applicable norms The guarantee does not apply if this product is installed in any other way than is indicated by Fancom ...

Page 6: ...required ventilation percentage can be determined in a Fancom climate controller This ventilation percentage could be based on the direction sensitive rotation feedback DSR feedback The fan is connected to the IVM Touch with the IVM Touch 230V 2T10 it is possible to control two fans separately The IVM Touch distinguishes between five types of Fancom control principles IVM Touch 24Vac IVM Touch 230...

Page 7: ...ply etc Never mount the IVM Touch near water pipes drainage pipes etc Never mount the IVM Touch in a humid and or dusty room and certainly not in the room where the animals are present Mount the IVM Touch at such a height that you can control the IVM Touch easily eye level and square on a solid backing The cable glands and wiring should be positioned at the bottom Mount the IVM Touch as follows 1 ...

Page 8: ...the entry of moisture dust and or aggressive gasses Check that the mains voltage and frequency for which this Fancom controller is suitable see chapter Technical Specifications in this manual correspond to the mains voltage and frequency on site Be sure that the IVM Touch is properly grounded When using metal cable trays grounding at one point of the tray is recommended The IVM Touch should be pos...

Page 9: ...menu 3 Tap the number to edit the value 4 Set the required I O address by using 5 Tap to confirm If the IVM Touch is the first or last unit of the IO net switch the Termination resistor dipswitch on the ICM board to ON Set the ventilation control type as follows 1 Enter the Installation menu see Working with the IVM Touch page 13 2 Scroll down to the Control type menu 3 Tap the setting to edit the...

Page 10: ...he unit type as follows 1 Enter the Installation menu see Working with the IVM Touch page 13 2 Scroll down to the Unit type menu 3 Tap the setting to edit the value 4 Set the required unit type by using 5 Tap to confirm Set the maximum revolutions as follows 1 Enter the Installation menu see Working with the IVM Touch page 13 2 Turn the rotary knob to manual 3 Scroll down to the Max RPM menu ...

Page 11: ...an will run at high speed for a maximum of 60 seconds 7 Wait until the following screen appears If the adjustment has been unsuccesfull the following screen appears The most common cause is that the IVM Touch has measured none or too few pulses Check the DSR feedback sensor and repeat the adjustment procedure ...

Page 12: ...M Touch to 1 the minimum position the fan is barely running 99 the maximum position the fan is only just running at high speed or 95 of the mains voltage 5 Tap to confirm and wait until the screen below is shown 6 Repeat the steps above to set the 99 triac settings 7 If needed repeat the steps above to set the 1 and 99 settings for the seconds triac control IVM Touch 2T10 8 Set the rotary knob of ...

Page 13: ...log control measure screen appears Check the voltage 1 the voltage should be between 9 and 10V with a 0 10V control this is between 0 1V and 1V 99 the voltage should be between 0 1 and 1V with a 0 10V control this is between is 9V and 10V 5 Tap to confirm and wait until the screen below is shown 6 Repeat the steps above to set the 99 settings 7 Set the rotary knob on the front of the IVM Touch to ...

Page 14: ...riac IVM Touch address 1 Analog output 1 IVM Touch address 2 Analog output 2 IVM Touch address 3 Triac 1 IVM Touch address 4 Triac 2 IVM Touch address 5 After an address has been changed the network module should always be restarted power off on Set the dipswitch settings on Print ICM board There are two options for controlling the speed of the fans Either the speed is based on the temperature sen...

Page 15: ... independent control Depended both fans are controlled simultaneous Independed each fan is controlled seperate controllable via I O net Set the dipswitches for dependend independed as follows Board 1 Board 2 Control type Triac Bypass Triac Bypass Dependend 1 1 1 1 Independend 1 1 2 2 1 Check whether the IVM Touch has been connected correctly 2 Check whether the IVM Touch works optimally ...

Page 16: ...escribes the main parts and the operation of the IVM Touch The IVM Touch can be operated on the touch screen 1 Touch screen 2 Manual Automatic rotary knob 3 Manual Off Automatic switch only IVM Touch 230V and 2T10 variants ...

Page 17: ...tor If an alarm occurs the alarm icon in the bar will flash red Enter Installer menu Tap The Version menu appears Tap the right bottom corner This is an invisible button The Installer menu appears Exit Installer menu Tap to exit the Installer menu and enter the User menu 2 Working area Displays the data of user or installation settings of the IVM Touch 3 Control buttons Provides buttons to insert ...

Page 18: ...per function see the table below The switch is only available with IVM Touch 230V variants The IVM Touch 230V 2T10 has two switches one for each triac output By independent use the second triac output does not act to the rotary knob but is only controllable with the climate controller in this case the switch functions normal Knob Switch Fan Vortex damper Controlled by Controlled by A A Climate con...

Page 19: ...factory settings using the following steps Set IVM Touch on manual control Set IO net adress 5x to 0 IVM Touch will restart using factory settings If more than one alarm occurs a combination of the alarm indications becomes visible e g Backup alarm DSR defect A control computer connected to the IVM Touch via an I O network can take over the alarm notification as long as this functionality is suppo...

Page 20: ... of the actual day number Readout of the relay status heating cooling Readout of the house temperature The IVM Touch can also show the alarm messages Readout of house alarm Readout of all system alarms The availability of this additional function dependents on which Fancom climate controller is used A restart is needed before the IVM Touch shows the information and alarm messages ...

Page 21: ... 2 Analog in Voltage 0 10Vdc max 12Vdc Temperature sensor type S7 50C 150C Max open contact voltage 4Vdc 1 DSR feedback Pulses 4 puls per revolution Max frequency 200Hz Max open contact voltage 12Vdc 1 Digital input Pulse input Max frequency 20Hz Max open contact voltage 12Vdc 1 Auto manual control Manual ventilation between 0 100 Outputs 1 Power outage relay Max 30Vac dc Max 2Amp 2 Relay Max 240V...

Page 22: ... O network Possibility of communication via the I O network One control computer and a maximum of 31 network modules may be connected to the I O network Each connected network module has a unique address After an address has been changed the network module should always be restarted power off on 1 Touch screen 2 Manual Automatic rotary control knob 3 ICM 24V board ...

Page 23: ...log in 2 Analog out 1 Vortex damper iFan Vortex damper Vortex damper Vortex damper Analog out 2 Fan 10 0V Fan 10 0V Fan 10 0V Digital in RTTM DSR feedback DSR feedback DSR feedback DSR feedback I O I O net I O net I O net I O net I O net Alarm Alarm Alarm Alarm Alarm Alarm RL 1 RL 2 24 Vac Power supply Power supply Power supply Power supply Power supply Other I O connections are free to use ...

Page 24: ...G 21 g 1 Touch screen 2 Manual Automatic rotary control knob 3 Manual Off Automatic switch 4 Triac board 5 ICM 230V board Print ICM 230Vac board ...

Page 25: ...G 22 g Triac T10 board Triac T6 board ...

Page 26: ...k DSR feedback DSR feedback I O I O net I O net I O net I O net I O net Alarm Alarm Alarm Alarm Alarm Alarm RL 1 RL 2 230V L N triac board L N triac board L N triac board L N triac board L N triac board Triac board L N 230V ICM board 230V ICM board 230V ICM board 230V ICM board 230V ICM board L Z Fan Fan Fan Fan Fan L L1 N N2 Mains supply 230V Mains supply 230V Mains supply 230V Mains supply 230V ...

Page 27: ...G 24 g ...

Page 28: ...G 25 g ...

Page 29: ...G 26 g ...

Page 30: ... that the IVM Touch Complies with the provisions of the 1 Low voltage directive 2014 35 EU according to NEN EN IEC 61010 1 2010 2 EMC directive 2014 30 EU Emission according to NEN EN IEC 61326 1 2013 Immunity according to NEN EN IEC 61326 1 2013 Place Panningen Date 08 02 2019 Paul Smits Managing Director ...