G
9
g
The triac and analog screens may differ from your screen, as the controller only shows parts that have
been installed.
Set the triac settings as follows:
1. Enter the
Installer
menu (see "Working with the IVM-Touch" page 13).
2. Scroll down to the
Triac
menu.
3. Tap
. The adjustment screen is shown.
4. Turn the rotary knob of the IVM-Touch to:
1%: the minimum position (the fan is barely running).
99%: the maximum position (the fan is only just running at high speed or 95% of the mains voltage).
5. Tap
to confirm and wait until the screen below is shown.
6. Repeat the steps above to set the 99% triac settings.
7. If needed, repeat the steps above to set the 1% and 99% settings for the seconds triac control (IVM-Touch
2T10).
8. Set the rotary knob of the IVM-Touch to
A
(Automatic).
If the triac setting is not approved the alarm screen is shown. Check if the settings are correct.