54
Using the system
Centrali anti-intrusione
• From the Alien keypad - access the “Apps” section by tapping the button
, then
tap the “Photo frame” button.
• Automatically, if the value set for the “Delay photo” parameter is different from
“Disabled”.
In order to change this parameter and others of the Alien keypad and the
application, access the “Settings” section by tapping the button
, type-in a
user code and then access the “Alien” section (see paragraph 5-8 Keypad settings).
The slideshow can be stopped by tapping the screen, which returns to the home page.
5-24
Graphic maps
The SmartLiving supervision functions are based on graphic maps which can accessed
by the end-user through an Alien keypad or web interface.
The graphic maps are linked together in a tree structure that allows you to view the status
of every part of the security system status and interact with it through the icons shown.
The Alien keypad manage up to 10 maps (versions previous to 2.00 manage up to 5
maps) and the web interface as many as 20 maps. Each map supports up to 20 objects/
buttons represented by icons.
The type of icon used and its function at default as a button is described in the following
table. It is possible to change these functions during the programming phase and
associate each icon with a descriptive string or even make use of customized icons.
Note
The Graphic map functions require installation of a micro-SD board.
If this board is not installed the MAPS button will show the message “no SD-card” and the
application will not start.
Table 5-6: Graphic map icons at default
Subject
Icon
BUTTON
Subject
Icon
BUTTON
Link
Link to the Alien
home page
Scenario
Scenario active
/
Map link
Scenario inactive
After a valid code entry you can
activate the scenario
Partition
Partition armed in
Away mode
After a valid code
entry a window will
open where you can
select the arming
mode you wish to
apply.
Ongoing
fault
Scenario active
Accesses the faults viewing sec-
tion
Partition armed in
Away mode
Scenario inactive
Partition armed in
Instant mode
Thermo-
stat
Thermostat dis-
abled
Accesses the reader thermostat
management section
Partition dis-
armed
Thermostat set to
manual mode
Partition alarm/
tamper memory
Thermostat set to
daily mode
Zone
Zone shorted/
tamper
Zone alarm/tam-
per memory
After a valid code
entry the zone will
change its activation
status
Thermostat set to
weekly mode
Zone in stand-by
status
Thermostat set to
antifreeze mode
Zone in alarm
status
Reset
partitions
After a valid code entry you can
deactivate immediately the out-
puts relative to alarm and tam-
per events and clears the alarm
and tamper memory
Zone disabled/
bypassed
Clear call
queue
After a valid code entry you can
clear the call queue completely
and interrupt any ongoing call.