Microprocessor Controller
84
5. Replace security strip. Then carefully mount new EPROM chip and tighten security strip.
6. Place new EPROM chip ID label over old label on the side of the controller to identify new EPROM.
7. Install datalogger (or back cover) mounting screws.
8. Connect battery power plug to top of controller.
NOTE: The EPROM replacement will lead to a total loss of the software, thus software has to be
downloaded.
Replacing the Microprocessor Controller
NOTE: There are several programmable features that may need to be set to completely configure the
unit to customer specifications. Customer requirements may include features such as the container
identification number. Adjust any additional programmable settings to customer requirements before
releasing the unit for service.
1. Turn the unit On/Off switch OFF. Then unplug the unit power cord from the power supply.
2. Disconnect battery power connection from the controller (top plug on the controller).
3. Disconnect the communication cables from the controller, datalogger and remote monitoring modem.
4. Remove the screws that secure the datalogger (MPC2000 and MP3000 controller only) and remote
monitoring modem to the controller.
5. Remove the screws that secure the controller to the inside of the control box door.
6. Remove the controller from the door.
7. Install the replacement controller in the door using the existing hardware. Connect the keyboard cable
to the controller.
8. Install the datalogger (MPC2000 and MP3000 controller only) and remote monitoring modem to back
of the controller.
9. Connect the communication cables to the datalogger, remote monitoring modem and controller.
NOTE: Be certain that all connector plugs are fully seated.
CAUTION: EPROM chip replacement will lead to a total loss of software. Immediately proceed
to procedure for “Loading Controller Software” in this chapter.
CAUTION: Be sure to enter the container ID before releasing the unit for service. The
container ID is required to identify the data downloaded from the controller datalogger via a
laptop computer or a REFCON remote communications system.
CAUTION: Immediately proceed to procedure for “Loading Controller Software” in this
chapter.
Summary of Contents for Thermo King CRR DF MPC2000
Page 5: ...4 ...
Page 11: ...List of Figures 10 ...
Page 13: ...Introduction 12 ...
Page 19: ...Safety Precautions 18 ...
Page 21: ...Service Guide 20 ...
Page 47: ...Unit Description 46 ...
Page 97: ...Microprocessor Controller 96 ...
Page 101: ...Electrical Maintenance 100 ...
Page 141: ...Structural Accessory Maintenance 140 ...
Page 147: ...Refrigeration System Diagnosis 146 ...
Page 150: ...149 CRR DF MPC2000 Controller Diagram ...
Page 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Page 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Page 153: ...152 CRR DF MP3000A Controller Diagram ...
Page 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Page 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Page 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Page 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Page 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...