![Ingersoll-Rand Thermo King CRR DF MPC2000 Maintenance Manual Download Page 60](http://html.mh-extra.com/html/ingersoll-rand/thermo-king-crr-df-mpc2000/thermo-king-crr-df-mpc2000_maintenance-manual_2060249060.webp)
Microprocessor Controller
59
•
F3 key: BACKWARD/DOWN ARROWS indicate that pressing the K3 key scrolls the cursor
backward and/or downward through text boxes and menu lists.
•
F4 key: ENTER ARROW indicate that pressing the K4 key moves the cursor into the next menu
level or into a menu item text box.
5. Four special keys:
•
C/F key: Press to view alternate temperature scale in LED display.
•
DEFROST key: Press to initiate defrost. Evaporator coil temperature must be below 10 C (50 F).
•
SUP/RET key: Press to view alternate return/supply sensor temperature in LED display.
•
SETPOINT key: Press to show Setpoint temperature line in LCD display for setpoint adjustment.
6. Control Transformer: Low voltage control power and ground is supplied to the microprocessor
controller and the main relay board.
7. Main Relay Board: High voltage supply power and low voltage control power and ground are
supplied to the main relay board. The main relay board contains:
•
Relays to energize and de-energize unit contactors and solenoids. Component relays include the
heater, evaporator fan motor, condenser fan motor, and phase reversal relays.
•
Supply power circuit protection:
20 amp fuses (3) protect the high voltage circuits on the main relay board.
•
Control circuit fuse and circuit breaker protection:
- 7 amp manual reset circuit breaker protects the 29 Vdc control circuit.
- 2 amp fuse protects the 28 Vac control power circuit to the controller.
- 2 amp fuse protects the battery charger output circuit to the controller.
•
Electronics for measuring phase sequence.
•
Electronics for measuring amperage.
•
Electronics for measuring voltage.
•
Zero current transformer for earth leaking measurement.
8. Replaceable sensors: Return air, supply air, evaporator coil (defrost), ambient air, R-134a compressor
discharge line and R-23 compressor discharge line temperature sensors are field replaceable. Three
(replaceable) spare sensor receptacles are also provided for USDA temperature recording.
9. Defrost cycle control (see “Defrost System” in this chapter).
10. Pretrip (PTI) test capability (see “PTI (Pretrip) Test” in this chapter).
11. Data recording capability: The MPC2000 Datalogger and MPC2000ID Integral Datalogger can
record sensor temperatures as well as loss of power, alarms, unit operating modes, sensor failure,
setpoint change and unit shutdown indications. All data recordings are stored in memory. DRU-II or
SmartSponge software downloads and reports the return, supply, ambient and USDA sensor
temperatures as standard.
Logging intervals are selectable from 1 minute and 1/2, 1, 2 or 4 hours. When a 1 hour logging
interval is selected, the datalogger memory can store approximately 365 days of information. The
logging of USDA sensors is fixed at 1 hour intervals to comply with USDA requirements.
Summary of Contents for Thermo King CRR DF MPC2000
Page 5: ...4 ...
Page 11: ...List of Figures 10 ...
Page 13: ...Introduction 12 ...
Page 19: ...Safety Precautions 18 ...
Page 21: ...Service Guide 20 ...
Page 47: ...Unit Description 46 ...
Page 97: ...Microprocessor Controller 96 ...
Page 101: ...Electrical Maintenance 100 ...
Page 141: ...Structural Accessory Maintenance 140 ...
Page 147: ...Refrigeration System Diagnosis 146 ...
Page 150: ...149 CRR DF MPC2000 Controller Diagram ...
Page 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Page 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Page 153: ...152 CRR DF MP3000A Controller Diagram ...
Page 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Page 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Page 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Page 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Page 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...