Microprocessor Controller
76
•
Set Log Time: The current Log Time interval appears in the screen. To enter a new log interval:
a. Press F4 key with cursor in Log Time menu line. Cursor moves to the end of the menu line and
flashes.
b. Press F3 key to scroll through a list of log time intervals:
•
1 Minute
•
1/2 Hour
•
1 Hour
•
2 Hour
•
4 Hour
c. When the correct log time appears in the menu line, press and hold F4 key until cursor stops
flashing. The new Log Time appears in the display.
6. Press ESC key to exit any screen in the Datalogger menu.
RMM State Menu
The RMM (Remote Monitoring Modem) State menu displays the current communications status with a
REFCON system:
•
Offline: No communication between Controller-RMM and REFCON system.
•
Zombie: The controller has detected a REFCON system master module and is waiting for
communication.
•
Online: The Controller-RMM is logged-in on a REFCON system for online viewing.
Viewing the RMM State screen:
With the unit On/Off switch ON and the LCD display showing the standard display (setpoint):
1. Press the F1 key to retrieve current unit performance data before entering Main Menu.
2. Press F2 key to enter the menu list. Press F2 key to scroll through Main Menu until “RMM STATE”
appears in LCD display.
3. Press F4 key to access the RMM State screen. The screen will show: Offline, Zombie or Online.
4. Press ESC key to exit the RMM State screen.
Summary of Contents for Thermo King CRR DF MPC2000
Page 5: ...4 ...
Page 11: ...List of Figures 10 ...
Page 13: ...Introduction 12 ...
Page 19: ...Safety Precautions 18 ...
Page 21: ...Service Guide 20 ...
Page 47: ...Unit Description 46 ...
Page 97: ...Microprocessor Controller 96 ...
Page 101: ...Electrical Maintenance 100 ...
Page 141: ...Structural Accessory Maintenance 140 ...
Page 147: ...Refrigeration System Diagnosis 146 ...
Page 150: ...149 CRR DF MPC2000 Controller Diagram ...
Page 151: ...150 CRR DF MPC2000 Main Relay Board Electrical Diagram ...
Page 152: ...151 CRR DF MPC2000 Unit Wiring Schematic Low Speed Winding ...
Page 153: ...152 CRR DF MP3000A Controller Diagram ...
Page 154: ...153 CRR DF MP3000A Main Relay Board Electrical Diagram ...
Page 155: ...154 CRR DF MP3000A Unit Wiring Schematic Low Speed Winding ...
Page 157: ...156 CRR DF Refrigeration System Components Page 2 of 2 ...
Page 161: ...160 CRR DF Full Cool Flow and Pressure Diagram Page 2 of 2 ...
Page 163: ...162 CRR DR Evacuation Station and Unit Connections Page 2 of 2 ...