S3 Fault Descriptions
2.0 Faults
An Intellisys S3 – A
WARNING
will not shutdown the compressor. The warning will
remain on the display until acknowledged. It can be cleared by pressing the “C” clear key. A log will
be retained of the warnings / trips that have occurred. An Intellisys S3
TRIP
will shutdown the
compressor and must be manually cleared by pressing the “C” clear key. The trips will remain on the
display until acknowledged. The trips displayed will take precedence over the warnings. A log will be
retained of the warnings / trips that have occurred.
Trip Faults Comments
ENH
Motor Reverse Rotation
- Sump pressure has not indicated a positive pressure, 2 seconds
after the machine has loaded, first time after a power-up. This time is increased to 6 seconds if the
soft starter option is turned on. Once correct motor rotation is verified, this is not checked again until
power is removed from the controller.
STD
Emergency Stop
- Emergency Stop low level contact has opened.
STD
Motor Overload
- Main motor or Fan motor Overload contact has opened.
STD High Package Discharge Pressure
– refer to table in section 12 - (Not Adjustable, Information
Only)
STD
High A/E Discharge Temperature
- refer to table in section 12 - (Not Adjustable, Information
Only)
STD
Low Ambient Temperature
- The air-end temperature sensor is measuring a temperature less
than 2°C. The compressor will be in an alarm state and not start if the temperature is below 2°C. The
compressor will start if the temperature is above 2°C. This is only active if Low Ambient, LA, option is
installed.
ENH
Low Sump Air Pressure
- The sump air pressure has not increased above 15 psi. This is
measured 15 seconds after starting and operational anytime the compressor is running.
ENH
High Sump Air Pressure
- refer to table in section 12 (Not Adjustable, Information Only)
STD Discharge Pressure Sensor Failure
- The discharge pressure sensor input reading is beyond
the normal measurement range below 3.4 ma or above 20.8 ma.
ENH
Sump Pressure Sensor Failure
- The sump pressure sensor input reading is beyond the
normal measurement range below 3.4 ma or above 20.8 ma.
STD
/
ENH
Sensor Calibration Failure
- A sensor calibration has been attempted and the measured
value is outside of the +/- 10 % Full Scale value.
ENH Motor PTC Trip
The motor TC is open due to high motor Temperature.
Warning Faults
STD
High Package Discharge Pressure - refer to table 12 (Not Adjustable, Information Only)
ENH
High Sump Pressure – refer to table 12 (Not Adjustable, Information Only)
STD
High Air end Discharge Temperature - refer to table 12. (Not Adjustable, Information Only)
STD
Maintenance Due soon - refer to table 12 (Not Adjustable, Information Only)
STD
Maintenance Due immediately - refer to table 12 (Not Adjustable, Information Only)
ENH
Change Oil Filter -
ENH
Change Inlet Filter -
ENH
Change Separator Filter -
ENH
Integral Sequencing Communication Failure -
Summary of Contents for R110IU-10
Page 5: ...5 S3 Intellisys Controller Operating Instructions...
Page 6: ...6 Software Navigation...
Page 7: ...7 Eiger Controller Fault Indicators 020 Tr Motor PTC Open High Motor Temperature...
Page 14: ...14 Star Delta Wiring Diagram...
Page 15: ...15...
Page 16: ...16 Soft Start Wiring Diagram...
Page 17: ...17...
Page 18: ...18 Line Start Schematic...
Page 19: ...19...
Page 20: ...20 Process and Instrumentation Diagram...
Page 21: ...21...
Page 28: ...28 Maintenance...
Page 29: ...29 Maintenance...
Page 30: ...30 Maintenance...
Page 31: ...31 S3 Controller Input Output Overview AI Analog Input DI Digital Input DO Digital Output...
Page 45: ...45 Standard S3 Menu Structure and Parameters Table 12...
Page 46: ...46 Standard S3 Menu Structure and Parameters Table 12...
Page 47: ...47 Standard S3 Menu Structure and Parameters Table 12...
Page 49: ...49 Modbus Register Listing...
Page 50: ...50 Table 13 Modbus Register Listing...
Page 52: ...52 Appendix 1 Thermistor 2ATT 34 to 124 C 255 F Air end Discharge...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58 General Specifications for Eiger Packages...
Page 59: ...59...
Page 60: ...60...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...
Page 65: ...65...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...
Page 73: ...73...
Page 74: ...74...
Page 75: ...75...
Page 76: ...76...
Page 77: ...77...
Page 78: ...78...
Page 79: ...79...