11
.
Safety valve blows
when compressor
loads.
Minimum pressure valve
(MPV) stuck closed.
Strip the MPV, examine and
repair if necessary.
Blocked separator element
Check differential pressure
and replace element
Check the setting of the
safety valve and the rated
pressure.
Safety valve faulty
Motor reverse
rotation
Fault T 1
Emergency stop activated
Change any 2 of the
incoming power wires to
change motor rotation
Emergency Stop
Fault T 2
Incoming power wired to
package incorrectly
Clear fault hazard twist
emergency stop button to
reset.
Compressor will not start
below 2 deg C (28 deg F),
unless fitted with low
ambient option (
−
10_C)
(14 deg F)
Low ambient
temperature
Fault T 4
Wait until compressor
package air temperature
rises above minimum starting
temp requirement.
Blocked separator element
Blow down system
ineffective
Replace separator element
Check the operation of the
load solenoid valve.
Check un-loader valve
−
strip
and clean if necessary.
High sump air
pressure.
Faults T 5, W 5
MPV stuck closed
Strip MPV, examine and repair
if necessary.
Summary of Contents for R110IU-10
Page 5: ...5 S3 Intellisys Controller Operating Instructions...
Page 6: ...6 Software Navigation...
Page 7: ...7 Eiger Controller Fault Indicators 020 Tr Motor PTC Open High Motor Temperature...
Page 14: ...14 Star Delta Wiring Diagram...
Page 15: ...15...
Page 16: ...16 Soft Start Wiring Diagram...
Page 17: ...17...
Page 18: ...18 Line Start Schematic...
Page 19: ...19...
Page 20: ...20 Process and Instrumentation Diagram...
Page 21: ...21...
Page 28: ...28 Maintenance...
Page 29: ...29 Maintenance...
Page 30: ...30 Maintenance...
Page 31: ...31 S3 Controller Input Output Overview AI Analog Input DI Digital Input DO Digital Output...
Page 45: ...45 Standard S3 Menu Structure and Parameters Table 12...
Page 46: ...46 Standard S3 Menu Structure and Parameters Table 12...
Page 47: ...47 Standard S3 Menu Structure and Parameters Table 12...
Page 49: ...49 Modbus Register Listing...
Page 50: ...50 Table 13 Modbus Register Listing...
Page 52: ...52 Appendix 1 Thermistor 2ATT 34 to 124 C 255 F Air end Discharge...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58 General Specifications for Eiger Packages...
Page 59: ...59...
Page 60: ...60...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...
Page 65: ...65...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...
Page 73: ...73...
Page 74: ...74...
Page 75: ...75...
Page 76: ...76...
Page 77: ...77...
Page 78: ...78...
Page 79: ...79...