OPERATING INSTRUCTIONS
31
M200–LV M250–LV
STARTING THE MACHINE
Refer to the diagram T5443
Upon power up, the Intellisys will carry out a series of checks, and
the message CHECKING MACHINE will show on the display. If all the
check parameters are satisfactory, the display will then show READY
TO START.
Depress the start button (2) on the Intellisys unit. The machine will
start and automatically load.
STOPPING THE MACHINE
Refer to the diagram T5443
Depress the STOP button (3) which will automatically unload the
compressor for 10 seconds before stopping.
Switch off the main electrical isolation switch.
STOPPING THE MACHINE IN AN EMERGENCY
Refer to the diagram T5443
If the machine has to be stopped in an emergency DEPRESS THE
EMERGENCY STOP BUTTON (1) LOCATED ON THE
INSTRUMENT PANEL.
This will over–ride the normal unload/stop button and will
immediately stop the machine without the 10 second delay.
CAUTION: Never allow the machine to stand idle with pressure in the
system.
RE–STARTING AFTER AN EMERGENCY
If the unit has been switched off because of a machine malfunction,
then identify and correct the fault before attempting to re–start.
If the unit has been switched off for reasons of safety, then ensure
that the machine can be operated safely before re–starting.
Refer to the PRIOR TO STARTING and STARTING THE
MACHINE instructions earlier in this section before re–starting the
machine.