OPERATING INSTRUCTIONS
24
M200–LV M250–LV
barg
–CURRENT STATUS–
7,5
barg
PACKAGE DISCHARGE TEMP
39
_
C
RUNNING LOADED
AIREND DISCHARGE TEMP
MODE: MOD/ACS
89
_
C
MAIN MENU
DISPLAY SCREEN
The display screen is divided into three functional areas, as seen
in the typical CURRENT STATUS screen shown here.
The left side continuously shows the package discharge pressure
in large numbers showing the running condition of the machine and the
line below that showing the present mode of operation.
The right side shows various items or lists such as the machine’s
CURRENT STATUS readings, the MAIN MENU, the OPERATOR
SETPOINTS list, etc. Any of the lists can be moved up or down by
pressing the arrow buttons to the right of the screen. The small arrow(s)
displayed in the upper right corner of the screen indicate when you can
move up and/or down through a list. The arrow buttons are also used
to change an individual item’s value. At certain times, items and/or their
values are “highlighted”. This means that they are displayed as light
characters on a dark background.
barg
–CURRENT STATUS–
7,5
barg
PACKAGE DISCHARGE TEMP
39
_
C
RUNNING LOADED
AIREND DISCHARGE TEMP
MODE: MOD/ACS
89
_
C
MAIN MENU
The bottom of the screen is divided into thirds with the words in each
small box showing the function of the button directly beneath it. The
words will change in these boxes depending on what actions are
permitted at any particular time. The action resulting from pressing
each of these buttons is indicated in the Operator Panel Flow Diagram
later in this section. This can be used as a quick reference of how to
step the controller screen through any desired function.
CURRENT STATUS
The CURRENT STATUS screen is considered to be the “normal”
display that the controller shows.
The following items and their present values can be displayed on the
right side of the screen by pressing the up and down arrow buttons.
CURRENT STATUS items
Package Discharge Temperature
Airend Discharge Temperature
Injected Temperature
Sump Pressure
Separator Pressure Drop
Coolant Filter
Inlet Vacuum
Inlet Filter
Total Hours
Loaded Hours
% Load Modulation
Software Title and Version