OPERATING INSTRUCTIONS
27
M200–LV M250–LV
OPTIONS
Options are turned on or off and their associated values are set
using the OPTION screen.
Some options require additional machine hardware and the correct
“Option Module” to plug into the Intellisys controller. Descriptions of the
options operations can be found later in this section. The name and
value of each of the following options can be seen by moving the list up
and down using the arrow buttons.
OPTIONS
Items
Range
Step
Unit
Power Out
Restart
ON/OFF
–
–
Power Out
Restart Time
10 to 120
1
SEC
Low Ambient
ON/OFF
–
–
Min. Cooler
Out Temp.
30 to 150
1
Deg.F
An
Option
item’s value can be changed the same way that
OPERATOR SETPOINTS values are changed.
–SENSOR CALIBRATION–
barg
7,5
barg
SENSOR 1AVPT
CALIBRATE
READY TO START
SENSOR 3APT
CALIBRATE
STATUS
MAIN MENU
SELECT
SENSOR CALIBRATION
Pressure sensor calibration is done through the SENSOR
CALIBRATION screen. Sensor calibration can only take place when
the machine is stopped. Calibration needs to be done only after a
sensor has been replaced or the Intellisys controller has been
replaced.
Each of the sensors listed below can be chosen by using the up and
down arrow buttons to highlight it on the screen.
SENSOR CALIBRATION Items
Sensor 1AVPT
Sensor 3APT
Sensor 4APT
Select the highlighted sensor by pressing the SELECT button.
Press the CALIBRATE button to start the automatic calibration
procedure, or press the CANCEL button to not calibrate it and return
to the sensor list.
The calibration screen can be exited by pressing either the STATUS
or MAIN MENU buttons. If no buttons are pressed within 30 seconds,
the display will return to the CURRENT STATUS screen.