USER MANUAL
Series HC
Reference IR - 222
Rev 3
Page 39
10/17/2013
SECTION 4:
(Continued)
4.4.5.3
AF-1400 and above (or optional HAF-1400)
Isolate the filter by closing the manual valves before and after the filter.
Completely depressurize the filter.
Open the handhole; be sure to have hold of the manway cover so as not to
lose it into the filter.
Remove the wing nut from the filter top plate(s) and remove the plate(s).
Remove the element(s) from the filter housing.
Inspect the filter base plate(s), t-bar(s), and filter union(s) (if applicable).
Replace as needed.
Install new element(s) to original position in housing.
Put back cover plate and wing nut.
Inspect o-ring or gasket. Replace if necessary.
Put back cover plate or yoke, then reattach yoke assembly and tighten.
Slowly repressurize the filter.
Check for air leaks with soap solution.
Place back into service.
4.5
FILTER ACCESSORIES
Advice
Pressure differential gauge:
Indicates the degree to which the elements are soiled.
Summary of Contents for HC-103
Page 2: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 2 10 17 2013 ...
Page 31: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 31 10 17 2013 SECTION 4 MAINTENANCE ...
Page 50: ......
Page 52: ......
Page 54: ......
Page 56: ......
Page 69: ...SAHARA MOISTURE TRANSMITTER Instruction Manual ...
Page 85: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 46 10 17 2013 SECTION 8 CUT SHEETS ...
Page 94: ...Page 4 MODEL 1700TM DIMENSIONAL PRINT 050205 Model 1700 IG ...
Page 119: ...USER MANUAL Series HC Reference IR 222 Rev 3 Page 47 10 17 2013 SECTION 9 DRAWINGS ...
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......